5
Subject to change without notice. Information without guarantee. / 07.01.2021
Important Information for installation
Set DALI Address Quantity
3.1 Press and hold down both of the two buttons until numeric digital display flashes, then release the button.
3.2 Click first button to select
“1
A
”
or
“2
A
”
which means 1 address or 2 addresses.
3.3 Then press and hold down any of the 2 buttons until the numeric digital display stops flashing to confirm the
setting.
For example, when we set address to 22:
When select 1A, both two channels will be the same address 22.
When select 2A, channel 1 will be address 22, channel 2 will be address 23.
Power on level is a DALI parameter that defines the level of a control gear after power is restored. The factory
default power on level for this driver is 100, which means the driver will be at 100% intensity when power is resto-
red.
Troubleshooting Help
Situation A: The power supply has been overloaded and is now in overload protection mode.
What does the error pattern look like?
The connected LEDs flash. You can reduce the brightness via a DALI software and the strip will stop flashing. You can
no longer control the colours with the software.
How can the problem be solved (two variants A + B)?
A. 1. Disconnect the device from the mains for at least 10 minutes. The unit will reset to factory settings.
2. Reduce the load so that it meets the specifications of the unit.
3. You can now operate the unit normally again.
B 1. Disconnect the device from the mains for at least 10 minutes. The unit will reset to the factory settings.
2. Disconnect the load (LED strip / LED module) from the power supply.
3. Reconnect the device to the mains.
4. Connect the device to the DALI Master software.
5. In the software, reduce the Power On Level and the maximum level for this device. The value must be below
the maximum load of the power supply.
6. Disconnect the device from the power supply and reattach the load.
7. You can now operate the device normally again.