background image

4. TouchLink

 

to

 

a

 

Zigbee

 

Remote

5. Removed from a Zigbee Network through Coordinator or Hub Interface 

From your ZigBee controller or hub 

interface, choose to delete or reset the 

lighting device as instructed. The 

connected light blinks 3 times to indicate 

successful reset.

Step 4: 

There shall be indication 

on the remote for successful link 

and connected light will flash 

twice.  

Zigbee

Remote

< 10cm

Step 2:

 Bring

 

the

 

remote or touch 

panel

 

within

 

10cm

 

of

 

the

 

lighting

 

device

.

Step 3

: Set the remote or touch 

panel into Touchlink 

commissioning, 

please refer to corresponding 

remote or touch panel manual to 

learn how

.

Note: 1) Directly TouchLink (both not added to a ZigBee network), each device can link with 1 remote. 

           2) TouchLink after both added to a ZigBee network, each device can link with max. 30 remotes.

           3) To control by both gateway & remote, add remote and device to network first then TouchLink.

           4) After TouchLink, the device can be controlled by the linked remotes.

6. Factory Reset Manually

Step 2

: Connected light 

will blink 3 times to 

indicate successful reset.

Step 1

: Short press “Reset.” 

key for 5 times continuously 

or reset power of the device 

for 5 times continuously if 

the “Reset” key is not 

accessible. 

Note:  1) If the device is already at factory 

default setting, there is no indication 

when factory reset again .

            2) All configuration parameters will 

be reset after the device is reset or 

removed from the network.

7. Factory Reset

 

through

 

a

 

Zigbee

 

Remote (Touch Reset)

Note

: Make sure the device already added to a network, the remote added to the same one or not added to any 

network.  

Step 1

: Reset power of the 

device to start TouchLink 

Commissioning, 180 

seconds timeout, repeat 

this step.

Step 4: 

There shall be indication 

on the remote and connected light 

flashes 3 times for successful 

reset.  

Zigbee

Remote

< 10cm

Step 2:

 Bring the remote or touch 

panel within 10cm of the lighting 

device

.

Step 3

: SSet the remote or touch 

panel into Touch Reset procedure 

to reset the device, please refer to 

corresponding remote or touch 

panel manual to learn how

.

8. Find and Bind Mode

Step 1

: Short press “Reset.” 

button 3 times (Or reset 

power of the device (initiator 

node) 3 times) to start Find 

and Bind mode (connected 

light flashes slowly) to find 

and bind target node, 180 

seconds timeout, repeat this 

step.

Zigbee

Remote

Step 2:

 Set the remote or touch 

panel (target node) into find 

and bind mode, and enable it 

to find and bind initiator, please 

refer to corresponding remote 

or touch panel manual

.

Step 3

: There shall be 

indication on the remote or 

touch panel that it bind the 

device successfully and can 

control it then

.

to learn how

.

Note: Make sure the device and remote already added to the same zigbee network.

9. Learning to a Zigbee Green Power Remote

Step 1

: Short press “Reset.” 

button 4 times (Or reset 

power of the device 4 times) 

to start Learning mode 

(connected light flashes 

twice), 180 seconds timeout, 

repeat this step.

Zigbee

Green Power

Remote

Step 2:

 Set the green power 

remote into Learning mode, 

please refer to its manual

.

Step 3

: Connected light will 

flash twice to indicate 

successful learning. Then the 

remote can control the device.

Note: Each device can learn to max. 20 zigbee green power remote.

Step 1: Method 1: 

Short press 

“Reset” button 4 times (or 
reset power of the device 4 
times) to start Touchlink 
commissioning immediately, 
180S timeout, repeat this step. 

Method 2: 

Reset power of the 

device, Touchlink 
commissioning will start after 
15S if it’s not added to a zigbee 
network, 165S timeout. Or 
start immediately if it’s already 
added to a network, 180S 
timeout. Once timeout, repeat 
this step.

L

N

pu

sh

sw

itc

h

L

L

N

N

OUT

L

N

A1-A2: 8-230V

AC 100-240V

Reset

L

N

pu

sh

sw

itc

h

L

L

N

N

OUT

L

N

A1-A2: 8-230V

AC 100-240V

Reset

L

N

pu

sh

sw

itc

h

L

L

N

N

OUT

L

N

A1-A2: 8-230V

AC 100-240V

Reset

L

N

pu

sh

sw

itc

h

L

L

N

N

OUT

L

N

A1-A2: 8-230V

AC 100-240V

Reset

L

N

pu

sh

sw

itc

h

L

L

N

N

OUT

L

N

A1-A2: 8-230V

AC 100-240V

Reset

Отзывы: