4. TouchLink
to
a
Zigbee
Remote
5. Removed from a Zigbee Network through Coordinator or Hub Interface
From your ZigBee controller or hub
interface, choose to delete or reset the
lighting device as instructed. The
connected light blinks 3 times to indicate
successful reset.
Step 4:
There shall be indication
on the remote for successful link
and connected light will flash
twice.
Zigbee
Remote
< 10cm
Step 2:
Bring
the
remote or touch
panel
within
10cm
of
the
lighting
device
.
Step 3
: Set the remote or touch
panel into Touchlink
commissioning,
please refer to corresponding
remote or touch panel manual to
learn how
.
Note: 1) Directly TouchLink (both not added to a ZigBee network), each device can link with 1 remote.
2) TouchLink after both added to a ZigBee network, each device can link with max. 30 remotes.
3) To control by both gateway & remote, add remote and device to network first then TouchLink.
4) After TouchLink, the device can be controlled by the linked remotes.
6. Factory Reset Manually
Step 2
: Connected light
will blink 3 times to
indicate successful reset.
Step 1
: Short press “Reset.”
key for 5 times continuously
or reset power of the device
for 5 times continuously if
the “Reset” key is not
accessible.
Note: 1) If the device is already at factory
default setting, there is no indication
when factory reset again .
2) All configuration parameters will
be reset after the device is reset or
removed from the network.
7. Factory Reset
through
a
Zigbee
Remote (Touch Reset)
Note
: Make sure the device already added to a network, the remote added to the same one or not added to any
network.
Step 1
: Reset power of the
device to start TouchLink
Commissioning, 180
seconds timeout, repeat
this step.
Step 4:
There shall be indication
on the remote and connected light
flashes 3 times for successful
reset.
Zigbee
Remote
< 10cm
Step 2:
Bring the remote or touch
panel within 10cm of the lighting
device
.
Step 3
: SSet the remote or touch
panel into Touch Reset procedure
to reset the device, please refer to
corresponding remote or touch
panel manual to learn how
.
8. Find and Bind Mode
Step 1
: Short press “Reset.”
button 3 times (Or reset
power of the device (initiator
node) 3 times) to start Find
and Bind mode (connected
light flashes slowly) to find
and bind target node, 180
seconds timeout, repeat this
step.
Zigbee
Remote
Step 2:
Set the remote or touch
panel (target node) into find
and bind mode, and enable it
to find and bind initiator, please
refer to corresponding remote
or touch panel manual
.
Step 3
: There shall be
indication on the remote or
touch panel that it bind the
device successfully and can
control it then
.
to learn how
.
Note: Make sure the device and remote already added to the same zigbee network.
9. Learning to a Zigbee Green Power Remote
Step 1
: Short press “Reset.”
button 4 times (Or reset
power of the device 4 times)
to start Learning mode
(connected light flashes
twice), 180 seconds timeout,
repeat this step.
Zigbee
Green Power
Remote
Step 2:
Set the green power
remote into Learning mode,
please refer to its manual
.
Step 3
: Connected light will
flash twice to indicate
successful learning. Then the
remote can control the device.
Note: Each device can learn to max. 20 zigbee green power remote.
Step 1: Method 1:
Short press
“Reset” button 4 times (or
reset power of the device 4
times) to start Touchlink
commissioning immediately,
180S timeout, repeat this step.
Method 2:
Reset power of the
device, Touchlink
commissioning will start after
15S if it’s not added to a zigbee
network, 165S timeout. Or
start immediately if it’s already
added to a network, 180S
timeout. Once timeout, repeat
this step.
L
N
pu
sh
sw
itc
h
L
L
N
N
OUT
L
N
A1-A2: 8-230V
AC 100-240V
Reset
L
N
pu
sh
sw
itc
h
L
L
N
N
OUT
L
N
A1-A2: 8-230V
AC 100-240V
Reset
L
N
pu
sh
sw
itc
h
L
L
N
N
OUT
L
N
A1-A2: 8-230V
AC 100-240V
Reset
L
N
pu
sh
sw
itc
h
L
L
N
N
OUT
L
N
A1-A2: 8-230V
AC 100-240V
Reset
L
N
pu
sh
sw
itc
h
L
L
N
N
OUT
L
N
A1-A2: 8-230V
AC 100-240V
Reset
Содержание SR-ZG9101SAC-HP-SWITCH