Sunricher SR-2411-ZG-DIM-A Скачать руководство пользователя страница 2

Step 1

: Remove the device from previous zigbee network if it has already been added to

otherwise

 

pairing

 

will

 

fail

.

 Please

 

refer

 

to

 

the

 

part

 "

Factory

 

Reset Manually

".

Step 2

: From your ZigBee Controller or hub interface, choose to add lighting device and enter Pairing mode as 

instructed by the controller.

Step 4

: LED indicator will blink 5 times and then 

stay solid on, then the device will appear in your 

controller's menu and can be controlled through 

controller or hub interface.

8. Factory Reset Manually

Step 2

: LED indicator will blink 3 times to indicate successful reset.

Step 1

: Short press “Prog.” key for 5 times continuously or re-power 

on the DALI bus power supply 5 times continuously if the “Prog.” key 

is not accessible. 

Note:  1) If the device is already at factory default setting, there is no indication when factory reset again .

            2) All configuration parameters will be reset after the device is reset or removed from the network.

DALI bus

AC Power

50/60Hz

Zigbee

Remote

< 10cm

6. TouchLink

 

to

 

a

 

Zigbee

 

Remote

Step 2:

 Bring

 

the

 

remote or touch 

panel

 

within

 

10cm

 

of

 

the

 

lighting

 

device

.

Step 3

: Set the remote or touch 

panel into Touchlink 

commissioning, 

please refer to corresponding 

remote or touch panel manual to 

learn how

.

Step 4

: There shall be indication on the remote for successful link and 

LED indicator will flash twice.

Note: 1) Directly TouchLink (both not added to a ZigBee network), each device can link with 1 remote. 

           2) TouchLink after both added to a ZigBee network, each device can link with max. 30 remotes.

           3) For Hue Bridge & Amazon Echo Plus, add remote and device to network first then TouchLink.

           4) After TouchLink, the device can be controlled by the linked remotes.

7. Removed from a Zigbee Network through Coordinator or Hub Interface 

From your ZigBee controller or hub 

interface, choose to delete or reset the 

lighting device as instructed. The 

connected light blinks 3 times to indicate 

successful reset.

DALI bus

L

N

DALI BUS PS

DA DA

DALI bus

AC Power

50/60Hz

L

N

DALI BUS PS

DA DA

AC Power

50/60Hz

L

N

DALI BUS PS

DA DA

+A1

DA

DALI OUTPUT

DA

ZigBee to DALI Controller

Prog.

A1-A2: 8-230V

-A2

IMP

Add.

Group

x1

x10

5

0

1

6

2

7

4

9

3

8

5

0

1

6

2

7

4

9

3

8

+A1

DA

DALI OUTPUT

DA

ZigBee to DALI Controller

Prog.

A1-A2: 8-230V

-A2

IMP

Add.

Group

x1

x10

5

0

1

6

2

7

4

9

3

8

5

0

1

6

2

7

4

9

3

8

+A1

DA

DALI OUTPUT

DA

ZigBee to DALI Controller

Prog.

A1-A2: 8-230V

-A2

IMP

Add.

Group

x1

x10

5

0

1

6

2

7

4

9

3

8

5

0

1

6

2

7

4

9

3

8

5. Zigbee Network Pairing through Coordinator or Hub

 (

Added

 

to

 

a

 

Zigbee

 

Network

)

Step 3

: power on the DALI bus power 

supply, the device will be set into 
network pairing mode (LED indicator 
flashes twice slowly), the network 
pairing mode will last until the device 
is added to a zigbee network.

Step 1: Method 1

: Short press “Prog” button (or re-power on the DALI bus power supply) 4 times to start 

Touchlink commissioning immediately, 180S timeout, repeat the operation. 

Method 2

: If the device is already added to a network, it will be set into Touchlink commissioning immediately, 

180S timeout. Once timeout, re-power on the DALI bus power supply to set it into touchlink commissioning 
again.

Содержание SR-2411-ZG-DIM-A

Страница 1: ... to be controlled the number equals to tens position plus units position 1 Select DALI Address Group Control Mode 1 A rotary switch is used to select Address Group control mode 2 When the rotary switch arrow is at Add position address control mode is selected 3 When the rotary switch arrow is at Group position group control mode is selected 2 Select DALI Address to be Controlled 1 When Address con...

Страница 2: ...ded to a ZigBee network each device can link with max 30 remotes 3 For Hue Bridge Amazon Echo Plus add remote and device to network first then TouchLink 4 After TouchLink the device can be controlled by the linked remotes 7 Removed from a Zigbee Network through Coordinator or Hub Interface From your ZigBee controller or hub interface choose to delete or reset the lighting device as instructed The ...

Страница 3: ...tart delete Learning mode LED indicator flashes slowly 180 seconds timeout repeat the operation Zigbee Green Power Remote Step 2 Set the paired green power remote into Learning mode please refer to its manual Step 3 LED indicator will flash 4 times to indicate successful deleting DALI bus 9 Factory Reset through a Zigbee Remote Touch Reset Note Make sure the device already added to a network the r...

Страница 4: ...hile connected with a push switch click the button to switch on off press and hold down the button to increase decrease light intensity between 1 and 100 Note 1 Each added device can link and be controlled by max 30 added remotes 2 Each added remote can link and control max 30 added devices 13 Setup a Zigbee Network Add Other Devices to the Network No Coordinator Required Step 1 Short press Prog b...

Отзывы: