Note: The below configuration MENU settings are the thermostat default settings – your installer may have changed one 
or more of these settings to suit your specific heating installation (e.g. Menu 06-Maximum Floor temp should be limited 
to 27C for wooden floor areas).

To enter into the setting menu, please follow these steps:

1. Turn the thermostat off by pressing              .

2. Press              and you will then see Menu 01.

3. Use              and              to adjust the sensor selection which is Menu 01 (Air Sensing, Air and Floor, or Floor Only.

4. Press              to move to the next Menu. One you have all the menu options set, proceed to the next step.

5. Press              to accept and store.

Configuration menu 

(only to be adjusted by/in consultation with your heating installer)

352 Morphett Road, Warradale

T

 08 8396 5617 

E

 [email protected]

Thermostat Setup Instructions

Menu #

Feature

Explanation

Recommended setting

01

Mode/Sensor Selection

This thermostat is a combination model which allows you to choose 3 

different modes.

A mode = Air Sensing (built-in sensor)

AF mode = Air & Floor Sensing (floor probe must be installed)

F mode = Floor sensing (floor probe must be installed)

F

02

Switching Differential

The number of degrees difference before switching. The default is 1°C 

which means the thermostat will switch the heating on 0.5°C below the set 

temperature and will turn it off 0.5°C above the set temperature. With a 2°C 

differential, the heating will switch on 1°C below the set temperature and 

will switch off 1°C above the set temperature.

1°C

03

Air Temperature Calibration

This is to recalibrate the air temperature if required.

0°C

04

Floor Temperature Calibration

This is to recalibrate the floor temperature if required.

0°C

05

Temperature Readout 

(AF mode only)

This gives you the option to show the Air Temperature, Floor Temperature 

or to show both Air & Floor at intervals.

A = air temperature 

F = floor temperature 

A-F = shows both air and floor 

in 5 second intervals

06

Maximum Floor Temp 
(AF mode only)

This is to protect the floor surface.

35°C

07

Temperature Format

This allows the temperature to be set as °C or °F.

°C

08

Clock Format

You can select the clock to show either 12 or 24 hour time.

24-hour (default), 

12- or 24-hour clock format

09

Frost Protection

This is to avoid your room temperature going below 5°C.

Off

10

5+2 / 7 Day Mode

This allows you to program either 5 days at once, then the 2 days of the 

weekend separately, or the full 7 days at the same time or 7 days separately.

02

Recommended configuration

Содержание SRT8

Страница 1: ...at press the power button When heating is no longer required press the power button to turn off the thermostat If you have an electric In Slab off peak system instead of turning the thermostat off you can simply turn off the floor heating Main Switch at your heating sub board If your thermostat screen is blank no display during the day there is no power to your thermostat and generally indicates y...

Страница 2: ...p 3 2 Use to adjust the day of the week you want to start programming or the day you wish to edit an existing program If all 7 days of the week are to have the same program press or press again to cancel 3 Press The LCD screen will display Program 1 and the time will be flashing 4 Use and to adjust the time you wish the Program 1 event to commence for the selected day days Each individual day of t...

Страница 3: ...n LCD If a reset is required the Configuration Menu should be also adjusted to SunRay s recommended settings for your application please consult for further advice Please contact SunRay Comfort 352 Morphett Road Warradale T 08 8396 5617 E sales sunraycomfort com au 5 Press and the temperature will start flashing 7 Press and the LCD screen will show Program 2 with the time display flashing Repeat s...

Страница 4: ...g Differential The number of degrees difference before switching The default is 1 C which means the thermostat will switch the heating on 0 5 C below the set temperature and will turn it off 0 5 C above the set temperature With a 2 C differential the heating will switch on 1 C below the set temperature and will switch off 1 C above the set temperature 1 C 03 Air Temperature Calibration This is to ...

Отзывы: