Box Contents: 

 
 

 

 

 

 

 

 
 
 
 
 
 

 
 
 
 
 

 

Qty 

Part # 

Description 

 

Qty  Part # 

Description 

SK-1220 

SunQuest solar panel 2ft x 20ft 

 

SK-FTG-D 

Threaded combination hose adapter 

 

 

SK-FTG-I 

"O" rings 

 

 

 

 

SK-FTG-F 

Threaded cap 

 

 

 

 

SK-FTG-J 

Rubber hose 7.5" 

 

 

 

 

SK-FTG-L 

Metal collar (Hose clamp) 

 

 

 

 

SK-FTG-E 

Roll of Teflon tape 

 

 

 

 

SK-INT-V 

Integrated by-pass valve 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Optional parts 

 
 

Roof Mounting Kit (SQ-RMK5)  

 

 

   High Wind Roof Mounting Kit (SQ-HWK) 

 
1 - SQ-RMK5 per SQ-2220 system is required for Roof 

 

    For high wind areas, to be used in addition to the roof mounting 

or Rack installation 

 

 

 

 

    kit (SQ-RMK5).  1 - SQ-HWK per SQ-2220 system is required 

 

 

 

 

 

 

 

    plus one extra. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Qty 

Part # 

Description 

 

Qty  Part # 

Description 

SK-RMK-ST-M 

Coated metal strap 

 

SK-RMK-BASE 

Mounting base 

15 

BOLT-Z 

Lag bolt 2" 

 

SK-RMK-CAP 

Mounting Cap 

 

 

 

 

SK-RMK-ST-N32 

Nylon strap 32" 

 

 

 

 

SK-RMK-ST-V32 

Vinyl strap 32" 

 

 

 

 

BOLT-Z 

Lag bolt 2" 

Содержание SQ-2220-ID

Страница 1: ...Model SQ 2220 ID INSTALLATION OPERATION MANUAL Read all the instructions before installing your solar heating system...

Страница 2: ...y from your pool or one story up then your pump may need to be 1HP or more Where can the solar panel be placed The solar panel can be placed on the ground Avoid placing in high traffic areas as it is...

Страница 3: ...ve Optional parts Roof Mounting Kit SQ RMK5 High Wind Roof Mounting Kit SQ HWK 1 SQ RMK5 per SQ 2220 system is required for Roof For high wind areas to be used in addition to the roof mounting or Rack...

Страница 4: ...Description 1 SK FTG A Threaded 2 way valve 4 SK FTG K Rubber hose 3 75 2 SK FTG B Threaded nipple 8 SK FTG L Metal collar Hose clamp 2 SK FTG C Threaded tee 1 SK VRV Vacuum Relief Valve 4 SK FTG D T...

Страница 5: ...ig 3a 4 Apply Teflon to threads of by pass valve SK INT V Screw side of valve with handle into the panel as per Diagram Step 3a Do not over tighten See Fig 3a 7 Loosen the union on the valve See Fig 3...

Страница 6: ...Put O rings SK FTG I on both combination adapters SK FTG D See Fig 3a 3 Thread both combination adapters into the panels as per Diagram Step 3b Do not over tighten See Fig 3a 4 Push the rubber hose yo...

Страница 7: ...ver See Fig 3a 10 Repeat for other end of panel Slide another metal collar onto the rubber hose Connect the 2 panels together by pushing the rubber hose over the second panel header Tighten metal coll...

Страница 8: ...ap for this type of installation Thread the cap into the panels as per Diagram Step 3d Do not over tighten See Fig 3a 2 If you are using flexible piping to connect panels to your pump then put O rings...

Страница 9: ...SK FTG K to connect the two set together as per Diagram Step 3d Install mounting kits as per instructions included with them Panels must be installed with a slight slope minimum 2 inch per 10 feet to...

Страница 10: ...tightened Unblock the inlet and outlet of your pool 5 Make sure the valve on the integrated diverter is on the open position See Fig C1 1 Valve in the open position Valve in the closed position Solar...

Страница 11: ...plied and connect it to the last open end of the diverter kit Place metal collar and tighten Connect the other end of the hose to your pool inlet Place metal collar and tighten See diagram C 2 7 Make...

Страница 12: ...that all your piping in drained 4 Run you feed and return PVC piping from your pool to your solar panels Make sure piping is installed in such a way to allow proper drainage 5 Make sure that your pipi...

Страница 13: ...losed turn your by bass valve in such a way to allow the water from your panels to drain Wait half an hour for panels to drain Unscrew the Vacuum Relief Valve or the Threaded cap at the top of the sol...

Страница 14: ...logies Inc Claims will not be accepted for a solar panel s damage in transit unless damage to shipping container is noted at time of delivery on the transport company s delivery bill Sunsolar Energy T...

Отзывы: