13.  Install cable management clips on module frames as shown.

 

      

14.  Transport modules to roof. 

15.  Remove the microinverter (MI) serial number sticker   

 and place it on your array layout diagram (ALD).

16.  Remove the module serial number sticker and place it  

 on your ALD.  

17. On each module, carefully raise the MI away from the backsheet 

until each side clicks into position. 

18. Position the first module of first row (the lower row in 

 

 a two-row array) on the rails, connect the trunk cable, and align the 

module on the rails with the marked array footprint. 

19.  Attach the end clamps to the first module. 

20.  Place the second module next to the first, raise its MI,   

 

 and connect the trunk cable. Add mid clamps.

21.  Continue installing modules till the end of the row,  

 cutting rails as necessary for the last module.  

    

22.  Complete wire management of the first row by fitting 

 

 the trunk cable into the pre-positioned cable clips.     

23.  Install two row-to-row spacers per module, on the  

 upper edge of each of the first row's modules. 

24.  Install the second (upper) row by repeating  

 Steps 15

21 of this QSG. 

25.  Install a row-to-row grounding clip between the two  

 rows, at one end of the array.     

If you need to make a connector: 

1.  Slide the nut over the cut cable end.

2.  Ensure that the grommet is in place inside 

the cover, and then slide the cover over the 

cable end. 

3.  Remove 1 1/16

 from the cable's outer 

sheathing. 

4.  Strip 3/8

 from the red conductor and from 

the black conductor.    

5.  Load the two terminals into the 12 GA slot of 

crimp tool, flush with the slots. 

 

 

 

 

 

 

 

 

6.  Fit the exposed conductors into the 

terminals and crimp them

DO NOT CRIMP 

OVER THE INSULATION!    

7.  Insert the terminals into the connector body 

until each clicks into place, and then tug on 

them to ensure they are secure.

8.  Slide the cover over the body until you feel it 

click into place.

9.  Tighten the nut to 62 in-lb (7 N-m).   

Important! 

When the connector is fully 

assembled, the cable outer sheathing must 

extend completely through the gasket inside 

the cover, and the gasket must fully cover the 

sheathing in order to prevent moisture from 

entering the connector.

      

                                                                                            

Note:

 For non-standard cable 

transitions use a 90° clip. 

E-Series and X-Series AC Modules

A-Series AC Modules