These  junction  boxes  have  been  designed  to  be  easily 

interconnected in series for their good connected cable and the 

connector  with  IP67  protection  grade.  Each  modules  has  two 

single conductor  wires, one positive and one negative,  which 

are  pre-wired  inside  the  junction  box.  The  connectors  at  the 

opposite  end  of  these  wires  allow  easy  series  connection  of 

Sunport’s  modules by  firmly  inserting the  positive  connector 

of a module into the negative connector of a Sunport module 

until the connector is fully seated. 

 

 

5.3.2 Cables 

Use  field  wiring  with  suitable  cross-sectional  areas  that  are 

approved  for  use  at  the  maximum  short-circuit  current  of  the 

module.  Sunport  recommends  installers  use  only  sunlight 

resistant cables qualified for direct current (DC) wiring in PV 

systems.

Satisfy  the  code  TÜV  2  PfG  1169

4mm²

Temperature range:-40

 to 

90

; Cables should be fixed 

to  the  mounting  structure  in  such  a  way  that  mechanical 

damage  of  the  cable  and/or  the  modules  is  avoided;  Do  not 

apply  stress  to  the  cables;  For  fixing,  use  appropriate  means, 

such  as  sunlight  resistant  cable  ties  and/or  wire  management 

clips  specifically  designed  to  attach  to  the  modules  frame. 

While the cables are sunlight resistant and  waterproof,  where 

possible, avoid direct sunlight exposure and  water immersion 

of the cables. 

 

5.3.3 Connectors 

Keep  connectors  dry  and  clean,  and  ensure  that  connector 

caps  are  hand  tight  before  connecting  the  modules.  Do  not 

attempt  to  make  an  electrical  connection  with  wet,  soiled,  or 

otherwise  faulty  connectors.  Avoid  sunlight  exposure  and 

water immersion of the connectors. Avoid allowing connectors 

to rest on the ground; Faulty connections can result in arcs and 

electrical  shock.  Check  that  all  electrical  connections  are 

securely  fastened.  Make  sure  that  all  locking  connectors  are 

fully engaged and locked. 

 

5.3.4 Bypass diodes 

The  junction  boxes  used  with  Sunport’s  modules  contain 

bypass diodes wired in parallel with the PV cell strings. In the 

case  of  partial  hot  spot,  the  diodes  bypass  the  current 

generated by the cells with hot spot, thereby limiting modules 

heating  and  performance  losses.  Bypass  diodes  are  not 

over-current  protection  devices.  In  the  event  of  a  known  or 

suspected  diode  failure,  installers  or  maintenance  providers 

should  contact  Sunport.  Never  attempt  to  open  the  junction 

box by yourself. 

 

6.MAINTENANCE    AND    REPAIR   

Sunport  recommends  that  PV  systems  shall  be  periodically 

inspected by the installer or qualified person. 

 

6.1 Maintenance 

Whether the glass is broken; Whether there is burning vestige 

on  the  backsheet;  All  cables  and  connector  attachments  are 

undamaged  and  properly  secured;  Mounting  and  grounding 

components are tightly secured with no corrosion. 

 

6.2 Repair 

In  order  to  reduce  the  potential  for  electrical  and  thermal 

shock,  Sunport  recommends  cleaning  modules  during  early 

morning  or  late  afternoon  hours  when  solar  radiation  is  low 

and  the  modules  are  cool,  especially  in  regions  with  high 

temperatures. 

 

When  modules  are  working,  there  should  not  be 

environmental  influence  factors  to  cast  shadows  and  cover 

part or even all of the modules, such as other modules, system 

support, bird drops and a lot of dust, clay or plant and so on, 

these may distinctly reduce the power output. Sunport advises 

that  there  should  be  no  obstructed  object  over  the  modules 

surface at any time. 

 

The  cleaning  frequency  depends  on  the  accumulated 

frequency of the fouling. In many instances the front surfaces 

of  the  modules  will  be  cleaned  with  the  rain,  and  we  can 

decrease  the  cleaning  frequency;  Sunport’s  modules  may 

contain  a  hydrophobic  anti-reflective  coating  on  the  glass 

surface  to  enhance  power  output  and  reduce  dirt  and  dust 

buildup;  In  order  to  avoid  module  damage,  do  not  clean  PV 

modules  with  a  power  washer  or  pressure  washer

it  is 

recommended to wipe the glass surface with a wet sponge or 

Содержание SPP M60S Series

Страница 1: ...the right to make changes to its products or this manual without prior notice Sunport is not responsible for any damages caused by inappropriate installation use or maintenance of Sunport modules incl...

Страница 2: ...Be cautious when setting the modules down onto a surface especially on the corner of the modules 4 2 Operating safety When unpacking the modules from the original package first remove the pallet lid a...

Страница 3: ...e You must stop using the module if there is exposed combustible gas nearby In the event of a fire modules may continue to produce a dangerous DC voltage even if they have been disconnected from the i...

Страница 4: ...lowest edge of the modules will not be covered by snow for long time In addition ensure that the lowest portion of the modules is placed high enough so that it will not be shaded by plants or trees or...

Страница 5: ...by the coefficient of 1 25 On the basis of lowest local temperature combine with temperature coefficient of voltage in manual Voc can be calculated When modules are in series voltage to be added up w...

Страница 6: ...tors are fully engaged and locked 5 3 4 Bypass diodes The junction boxes used with Sunport s modules contain bypass diodes wired in parallel with the PV cell strings In the case of partial hot spot th...

Страница 7: ...The installation manual applicable module types are as follows The module types are subject to changes without prior notice due to continuous product innovation research and development XXX shows the...

Отзывы: