Sunpentown SD-52PE Скачать руководство пользователя страница 3

 

2

BEFORE YOU USE YOUR DEHUMIDIFIER, PLEASE READ THIS INSTRUCTION 

MANUAL CAREFULLY. 

 
SAFETY PRECAUTIONS 
 
To prevent injury and property damage, the following instructions must be followed. 
Incorrect operation due to ignoring of instructions may cause harm or damages.  
 
The seriousness is classified by the following indications: 

  WARNING: This symbol indicates the possibility of death or serious injury. 

  CAUTION: This symbol indicates the possibility of injury or damage to property. 

 

------------------------------------------ 

 WARNING --------------------------------------------------- 

 
1.  Do not exceed the rating of the power outlet or connection device. 

2.  Do not operate or stop the unit by means of the power plug. 

3.  Do not use unit with damaged cord or connect unit to damaged electrical socket. 

4.  Do not modify power cord length or share outlets with other appliances. 

5.  Do not insert or remove plug with wet hands.  

6.  Do not use in the following locations: 

• 

Next to or near a heat source (radiator, heater, dryer, etc.) 

• 

Area where oil or water is likely to splash. 

• 

Under direct sunlight. 

• 

Near a bath, shower or swimming pool. 

• 

In a greenhouse. 

• 

Near flammable gas or combustibles, such as gasoline, benzene, thinner, etc. 

• 

Where chemicals are handled. 

7.  Disconnect power if strange sound, smell or smoke emits from the unit. 

8.  Never try to take apart or repair the unit by yourself. There are no user serviceable 

parts. 

9.  Always power off and unplug the unit before cleaning and maintenance. 

10. Do not drink or use the water drained from the unit 

11. Do not remove water bucket during operation. 

 

Содержание SD-52PE

Страница 1: ...DEHUMIDIFIER with BUILT IN PUMP MODELS SD 52PE SD 72PE INSTRUCTION MANUAL Please read these instructions thoroughly and keep it in a safe place for future reference ...

Страница 2: ...prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities A The municipality has established collection systems where electronic waste can be disposed of at free of charge to the user B The manufacturer will take back the old appliance for disposal at free of charge to the user C As old products contain valuable resources they may be sold to s...

Страница 3: ...h damaged cord or connect unit to damaged electrical socket 4 Do not modify power cord length or share outlets with other appliances 5 Do not insert or remove plug with wet hands 6 Do not use in the following locations Next to or near a heat source radiator heater dryer etc Area where oil or water is likely to splash Under direct sunlight Near a bath shower or swimming pool In a greenhouse Near fl...

Страница 4: ...ormation The manufacture s rating label is located on the back panel of the unit and contains electrical and other technical data specific to this unit Be sure the unit is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock Never remove the grounding prong Your unit must be used...

Страница 5: ...urs of operation To reset after cleaning the filter press the Filter button to turn off indicator light FAN Controls the fan speed Press to select Turbo high or Normal fan speed Set the fan to Turbo for maximum moisture removal When the humidity has reduced or when quiet operation is preferred set the fan speed to Normal POWER Press to turn the dehumidifier on and off UP DOWN Set humidity level Pr...

Страница 6: ...or additional 3 minutes then stop unit will resume when ambient humidity rises 5 above set humidity Auto Defrost When frost builds up on the evaporator coils the compressor will cycle off and the fan will continue to run until the frost disappears 3 Minute Delay After the unit has stopped or powered off there will be a 3 minute delay before it will resume operation again This is to protect the com...

Страница 7: ...oth Timer On and Off indicator lights are illuminated identifying both On and Off timers are now programmed o Turning the unit ON or OFF at any time or adjusting the timer setting to 0 0 will cancel any timer programs o Timer program is also cancelled when LED displays P2 error code IDENTIFICATION OF PARTS FRONT 1 Control panel 2 Air intake grille 3 Air outlet grille 4 Air filter behind the grille...

Страница 8: ... to help prevent moisture damage The dehumidifier must operate in an enclosed area to be most effective Close all doors windows and other outside openings to the room Casters Allow unit to move freely Do not force casters to move over carpet Do not move unit with water in the bucket as unit may tip over and spill water Before using the unit When running the unit for the first time operate the unit...

Страница 9: ...ause the unit to malfunction o When the bucket is removed and you notice water in the unit you must dry up the water o If the pump drops when you remove the bucket please reinstall the pump properly before replacing bucket Fig 3 o When the unit is operating and bucket is removed the compressor and fan will stop unit will beep 8 times and display will show Eb o When the unit is off and bucket is re...

Страница 10: ...er hose to the floor drain or suitable drainage facility Press the PUMP button to activate pump Pump will begin to operate when the water in the bucket reaches a pre determined level Note The pump may make some noise during initial operation 3 to 5 minutes This is normal Make sure the hose connection is secure so there will be no leaks Make sure the hose has no kinks or sharp bends Note If the Pum...

Страница 11: ...lace bucket in the dishwasher After cleaning make sure outside of bucket is dried off before replacing to its seat Clean the Air Filter Filter should be cleaned once every two weeks based on normal operating conditions First remove the bucket and pull filter downwards to remove Fig 12 Wash the filter with clean water and allow to air dry completely Re install the filter and replace bucket Caution ...

Страница 12: ...windows and doors are open Not enough time allowed to remove the moisture Humidity setting may be set too high Ambient temperature is too cold below 41 F Unit is noisy Unstable setting of unit or floor surface is not level Blocked filter Frost appears on coils This is normal The dehumidifier has Auto Defrost feature Water on floor Hose connection for continuous drainage or pump drainage is loose I...

Страница 13: ...cement parts will be new or reconditioned Parts which are replaced become the property of Sunpentown The warranty applies for the use of the product in the USA only What is NOT COVERED Warranty does not include freight charges Incidental or consequential damage caused by possible defects with this product Damage to product caused by improper power supply voltage accident fire floods or acts of nat...

Отзывы: