SUNLOVER HEATING 

WARRANTY – SL6 DELUXE 

 

This product is covered by a limited 3 year warranty against component failure or faulty 
workmanship from the date of installation. 
 
A faulty unit should be returned in the first instance to the dealer from which the unit 
was purchased. 
 
Damage to the unit due to misuse, power surges, lightning strikes or installation that is 
not in accordance with the manufacturer’s instruction may void the warranty. 
 
Warranty does not cover travel costs to or from installation site. Unit must be returned 
to manufacturer for repairs. 
 
If the power cord is damaged, do not use the controller; return the unit to the supplier 
for repair. 
 

Customer Record

. (To be retained by the customer); 

 
Dealer/Installer Name 

___________________________ 

 
Serial Number 

 

___________________________ 

 
Date Installed 

 

___________________________ 

 

For service assistance phone SUNLOVER HEATING 
 
VIC 

03 9887 2131

 

NSW 

02 9838 0000 

QLD 

07 5597 7360 

 
 

 

 

 

Factory 6

 

62 Parkhurst Drive, 

 

7-9 Activity Crescent, 

Knoxfield 3153 

 

 

Molendinar 4214 

Victoria Australia   

 

Queensland Australia

 

 

Unit 2

 

20-22 Foundry Road, 
Seven Hills 2147 
NSW Australia

 

 

www.sunloverheating.com.au

  

 

 

MODEL SL6RR Radio Remote Solar Controller  

With Time Clock

 

OPERATING INSTRUCTIONS 
Summer  Mode

  is  normal  operating  mode  used  during  the  Pool  Swimming  Season.  You  may  set  the 

desired pool  limit by pressing the UP or Down Buttons. The display shows the pool temperature then 
flashes the limit setting and light, the pump light and pump will be on when solar gain is available.  

 

Manual  Mode 

is  used  to  prime,  clean  or  test  the  pump.  To  select  manual  mode  press  the  SELECT 

button until the PUMP/MAN light is illuminated. The pump will then start, or stop if it has been running. 
To return to normal run simply press the SELECT button till the AUTO light is illuminated. The SL6RR 
will automatically return to AUTO run after 30 minutes, with a limit of 30 degrees.

 

 
Winter Mode 

should be selected when the pool is not being used for extended periods. The pump will 

be turned on for 3 minutes every day at the same time Winter Mode was selected. This will assist in the 
systems off-season maintenance and save energy. To enter this mode press the SELECT button till the 
WINTER light is illuminated. If the power is interrupted during winter mode the SL6RR will continue to 
count time accurately. The batteries in the transmitter may be removed if desired at this stage. 
 

Tropical Mode

 is used to assist in cooling over heated pools. If the limit has been reached, which is 

indicated  by  the  limit  light  on,  and  the  roof  temperature  drops  below  the  limit  temperature  (usually 
sometime  late  at  night)  the  pump  will  turn  on  and  pump  pool  water  to  the  roof  to  cool  it  down.  The 
pump  will  turn  off  when  the  pool  water  is  cooled  to  the  limit  setting.  To  set  this  function  press  the 
SELECT  button  till  the  TROP  light  is  illuminated.  To  switch  back  to  Summer  Mode  press  the  SELECT 
button till the AUTO light is illuminated. 

 

Roof Temperature 

When  selected,  the  roof  temperature  will  be  displayed  constantly  for  3  minutes  then  return  to  AUTO. 
The ROOF indicator will give 4 quick flashes when a signal is received from the transmitter. 
 

Transmitter / Battery Low 

When the SL6RR validates a received transmission, a flash from the Transmitter / Battery Low indicator 
will be seen. If the Transmitter / Battery Low indicator is on steady the batteries in the transmitter must 
be replaced before the unit will operate correctly in AUTO mode. 
 

OPERATION 

The SL6RR will turn the pump on when the roof temperature is higher than the pool (pipe) temperature 
by 8°C and off at 4°C. Roof temperature is received every seven minutes from the transmitter. When 
the pool temperature reaches the limit setting the limit light will flash, it will remain in this state while 
the roof is hot to prevent over heating the pool. The SL6RR will then wait till 8:00 AM the next day to 
start the process again. This function is to minimise the pool from  overheating, hence reducing water 
evaporation  and  consumption  of  chemicals.  An  auto  flush  program  is  incorporated  to  ensure  accurate 
pool  temperature  readings  are  obtained  as  the  pool  sensor  is  normally  located  well  away  from  the 
actual  swimming  pool  and  may  sit  in  direct  sunlight  or  in  warm  enclosures,  the  last  recorded  pool 
temperature will be displayed for 6 hours from when the pump was last running. When auto flush is in 
wait  mode  the  limit  light  will  be  on  constant  until  the  pump  is  turned  on  for  a  three  minute  test,  the 
pump light will flash until this test is over.  