SL6E CD INSTALLATION INSTRUCTIONS 

 

CONTROLLER: 

Find  a  suitable  location  to  mount  the  control  box.  The  controller  should  be 

installed out of direct weather and no closer than 3 meters from the water’s edge.  Lift up the 
two  mounting  tabs  and  use  two  appropriate  screws  to  mount  the  control  box  to  the  wall, 
keeping in mind that the power cable is 1.8m long and should be plugged directly into a general 
power outlet, not into an extension lead. Do not drill through the box. 
 

SOLAR  PUMP: 

The  solar  pump  plugs  into  the  left  side  240Vac  socket  marked  as  PUMP.  Note 

that the solar pump can only operate when the auxiliary power socket uses sufficient power to 
trigger  the  current  detection  circuit,  this  detection  trigger  point  can  be  adjusted  (see Installer 
Settings). 
 

FILTRATION PUMP: 

An Ioniser/Chlorinator or equivalent pump timer is to be plugged into the 

right  hand  side  240V  socket  (auxiliary)  located  under  the  POOL  &  ROOF  sensor  inputs,  the 
filtration pump plugs into the Ioniser/Chlorinator pump socket. 
 

TEMPERATURE SENSORS: 

The pool temperature sensor must be fitted into the suction line of 

the 

filtration

  pump,  as  close  to  the  pool  as  practical,  preferably  in  a  position  out  of  direct 

sunlight. It is recommended that a 14.5mm hole be drilled in the PVC pipe, this can be carried 
out using a Dontek PD01 grinding drill or a small pilot hole can be drilled and a 14.0mm drill-bit 
used spinning in a counter clockwise direction to minimize the chance of shattering pipe. Insert 
the grommet into the pipe and gently push in the black sensor barb. The green sensor plug is to 
be  fitted  to  the  plug  socket  marked  POOL,  in  some  cases  there  is  some  benefit  to  cable  tie 
30cm  of  wire  from  the  pool  temperature  sensor  to  the  pipe  and  insulate  this  section  (some 
ambient differences can travel up the tinned copper wire and affect the sensor reading). 
The

 

roof  temperature  sensor must be fitted into a small piece of solar collector or equivalent 

and attached to the roof.  The best location is within an arms length of the gutters edge of the 
house or shed as long as the sensor end is not shaded and is on a roof of similar aspect of the 
main collector. It 

must not

 be fitted on top of the solar collector or fitted to high points on the 

roof like Ridge Capping as false readings will be detected. 
The sensor plug is to be fitted to the right hand socket marked ROOF. Keep in mind that it is of 
the utmost importance to keep the roof temperature sensor cable as short as possible as this 
will assist in the longevity of the sensor and controller in the event of electrical storm activity 
and power surges. 

All temperature sensor cables must NOT be run parallel to power cables and should never be 
cable tied to power cables. 

All cable run lengths should be less than 50m if possible. Cable ties 

should be used to fasten the sensor cable to the cold water inlet pipe making sure that the ties 
are  approximately  10mm  from  PVC  fittings.  Cable  ties  should  be  tightened  only  firm,  over 
tightening  can  cause  breaks  in  the  outer  PVC  if  not  careful.  If  the  cable  is  to  be  run  under 
ground  a  conduit  must  be  used  to  protect  the  wire  and  there  is  to  be  no  cable  joins  within, 
conduit ends 

must

 be sealed to prevent water ingress. 

Any  excess  cable  should  be  removed  and  re-fitted  ensuring  that  the  wire  ends  are  tinned 
with solder. 

SL6E CD INSTALLER SETTINGS 

 

PUMP  LOAD SETTING: *** IMPORTANT ***

 The controller will not operate and will display a 

‘INSTALLER  MUST  SET  PUMP  LOAD’  message.  The  correct  Load  setting  is  required  for  this 
controller  to  pick  up  a  pump  which  is  failing  to  prime.  After  setting  the  load  values  test  by 
starting the solar pump in Manual Mode and ensure that the solar pump will switch off if the 
filtration pump fails to provide water.

 

Filtration Pump Load Automatic Setting:

 There are 2 methods for setting the load detection of 

the filtration pump. 

For automatic setting ensure the filtration pump is operating and primed. 

Then  simply  hold  the  UP  button  then press SELECT

, the unit will then display the pump’s load 

value  and  automatically  sets  the  threshold  levels  and  returns  to  automatic  operation,  if  the 
current  draw  of  the  filtration  pump  drops  below  this  level  then  the  solar  pump  is  forced  to 
switch off. 

Advanced Settings:

 To select the advanced settings, hold the DOWN button then press SELECT.  

Filtration  Pump  Load  Manual  Settings: 

If  setting  the  load  value,  please  ensure  your  filtration 

pump is connected to the auxiliary power socket (right hand side) and that the filtration pump 
is  primed  and  if  it’s  a  variable  speed  pump  ensure  the  filtration  pump  is  operating  at  the 
required  speed.  After  releasing  the  SELECT  button  the  LOAD=xxx  value  is  displayed  for  5 
seconds,  take  note  of  this  value.  When  the  LCD  screen  displays  RUN=>xxx  it  indicates  the 
minimum load required to allow solar to run, set this value 10% lower than the displayed LOAD 
value and press SELECT. The next value to adjust is TRIP> this is the overload value, when the 
filtration pump draws too much power (e.g. a variable speed pump operating too fast) then the 
solar pump is stopped. *Default is a RUN=>20 and trip >99. 
Once the Advanced settings have been adjusted all the above settings will be saved and the unit 
will restart. Re-adjust the temperature limit if required. 

Adjustable  differential: 

Special  note:  Adjusting  these  values  to  any  setting  other  than  the 

defaults may adversely affect the performance of this controller. To adjust the differentials hold 
the UP button while applying power to the unit. The first item prompted is to set the solar gain 
start  temperature  (RUN°  x)  this  setting  allows  the  pump  to  start  if  the  roof  temperature 
exceeds the pool temperature by this value, adjust with the UP/DOWN button, press SELECT to 
accept.  Next  you  will  be  prompted  to  set  the  differential  hysteresis  (END°  x)  which  turns  the 
pump off when roof temperature is less than the pipe temperature plus this value, adjust with 
the  UP/DOWN  button,  press  SELECT  to  accept.  Default  values  are  8° for RUN and 4° for END, 
these are the optimal values for maximum efficiency, some coastal locations may benefit from 
a reduced run value of 6°C for RUN and 4°C for END. 

Factory Test: 

To run the factory test, hold the SELECT button when first applying power, the unit will perform 
a series of self-diagnostic functions with the pump running. 
If there are any faults they will be reported on the display before the unit restarts into normal 
operation. 
 

Note: that this will force all settings to a factory default state. Re-enable time-clock if required 
also set the Pump Load value, temperature limit and operating mode to their required settings.

 

 