-31
12. BYTE
SUNLITRFID_ActiveScanIntervalSet(
BYTE Data
);
SUNLITRFID_ActiveScanIntervalSet
is used to set the scan interval time for active mode.
Parameters
:
Data
:
The value represents scan interval time,bwtween 5 ~ 255 (Uint
:
10mS)
Return Values
:
The function will return byte value that indicate the execution result, please see
「
MESSAGE
」
definition for byte value.
For example
:
BYTE byData;
byData=10;//scan interval=100ms
if(SUNLITRFID_
ActiveScanIntervalSet(byData)==HANDLE_SUCCESS)
{} //Set scan interval successfully
else
{}
13. BYTE
SUNLITRFID_ActiveScanIntervalGet(
BYTE *Data
);
SUNLITRFID_ActiveScanIntervalGet
is used to get the current scan interval time for active mode.
Parameters
:
Data
:
After executing the function ,The value represents the scan interval time that in active mode.
(Uint
:
10mS)
Return Values
:
The function will return byte value that indicate the execution result, please see
「
MESSAGE
」
definition for byte value
For example
:
BYTE byData;
if(SUNLITRFID_
ActiveScanIntervalGet(&byData)==HANDLE_SUCCESS)
{} //Get scan interval successfully
else
{}