background image

XX

T E M P E R AT U R E   G U I D E L I N E S

WHAT IS THE OPTIMAL TEMPERATURE?

AQuArium

Corals come from a variety of ocean environments, the temperature range would be from the low 

70s - low 90s. If you have a variety of corals from different environments, a temperature range of 

75 - 80 is a safe choice; if in doubt consult your aquarium dealer.

HYDrOPOniCs

Whether your hydroponic garden is an Ebb and Flow, Top-Feed drip, Aeroponic, nFT or deep 

Water Culture system; your plants will benefit by maintaining a consistent temperature of 60-70ºF. 

nutrient solutions maintained at 60-70ºF hold much more oxygen than a 75ºF solution. maintaining 

a temperature of 60-70ºF will help control transpiration rates and ensure proper nutrient uptake. 

never let your solution climb above 85ºF. Hot roots attract pests and diseases, as well as significantly 

reducing oxygen levels and nutrient uptake.

8

C.  The air filter needs cleaning at least once every month. The EcoPLus 

Chiller becomes dirty after being used for extended periods of time. 

Accumulated dirt makes the chiller’s exhaustion of heat less  

effective. Simply clean by washing the filter in clean  

water, or remove the dirt with a vacuum cleaner.

STORING THE ECOPLUS CHILLER

A.  When chiller is not in use,  

 discharge remaining water in pipes.  

Store chiller in safe place.

M A I N T E N A N C E

CLEANING THE AIR FILTER

A. ImPoRTAnT! disconnect the power.      B. Pull down air inlet grill from the top and take out filter.

Air inlet grill

Air filter

FUSE REPLACEMENT

A.  unscrew fuse cover. Replace old 15A-250V  

fuse with a new one (one replacement 

     fuse is included with each unit). Screw  

fuse and fuse cover back into place. 

Содержание Ecoplus

Страница 1: ...Chiller Installation and Operating Instructions Let the chiller unit set upright on it s feet for 20 minutes prior to plugging it in Failure to do so will damage the unit and void the warranty 1 2HP Chiller 1 4HP Chiller 1 10HP Chiller ...

Страница 2: ...__________ PRoduct name SERIAL NUMBER DATE OF PURCHASE ________________________________________________________________ name ________________________________________________________________ address ________________________________________________________________ city state zip ________________________________________________________________ phone number email Where you purchased this product _____...

Страница 3: ...rature for the sole purpose of identifica tion and does state or imply that the products are merchantable or fit for a particular purpose or that the products will conform to the descriptions PRODUCT SUITABILITY Many jurisdictions have codes and regulations governing sales construction installation and or use of products for certain purposes which may vary from those in neighboring areas While Sun...

Страница 4: ...82 5 79 75 71 5 68 64 5 61 Input Output Fuse Temp Control UP DOWN Air Vent Cover Release LCD Power 1 10 HP Voltage 120V 60Hz Wattage 280 Amps 2 3 Weight 31 lbs Dimensions 10 5 W x 12 D x 14 H Pump Size Minimum 132 GPH Maximum 264 GPH Chilling Capacity 93 gallons can chill the water up to 10ºF 35 gallons can chill the water up to 30ºF 1 10 HP TECH INFO 1 2 Fittings ...

Страница 5: ...120V 60Hz Wattage 480 Amps 4 Weight 48 5 lbs Dimensions 13 W x 15 D x 16 H Pump Size Minimum 633 GPH Maximum 1056 GPH Chilling Capacity 170 gal can chill the water up to 10ºF 100 gal can chill the water up to 30ºF 1 4 HP PERFORMANCE CURVES AIR TEMPERATURE WATER TEMPERATURE ºF Water Temperature Working Time Hours 100 Gallons 3 4 Fittings ...

Страница 6: ...ter Temperature Working Time Hours 100 Gallons 1 2 H P C H I L L E R F E AT U R E S C H I L L E R GENERAL INFORMATION A Micro computer with digital LCD display allows for easy operation B Features a titanium heat exchanger for optimum performance and corrosion resistance C High quality Japanese made compressor is extremely efficient and reliable D Suitable for cooling both fresh and salt water E C...

Страница 7: ...e air inlet is at least 12 distance from other objects and keep the heat exhaust window no less than 24 away from any object Do not block or cover air inlet or outlet A Take out water inlet outlet accessories B Assembling water inlet outlet C Attaching water inlet outlet to the unit D Connecting the external flexible hose If the EcoPlus Chiller is put in an aquarium cabinet the cabinet should have...

Страница 8: ... Don t overwork your chillers don t try to use at temperatures above 90ºF This is a ventilation issue you should address first Do not reduce the temperature setting on the chiller to lower than 40ºF E If in doubt of needed size get a bigger chiller unit or use two F Filter out debris with a pump filter bag Very Important G Use appropriately sized pumps you will need two One pump is to move water t...

Страница 9: ...starting temperature difference 1 Press the SET button for ten seconds to enter into the temperature adjustment function then press SET again to adjust the temperature difference 2 Press the p button and the system will exit in ten seconds displaying the water temperature 3 Press the q button to set the starting temperature difference you can adjust by 1 F increments with each press the starting t...

Страница 10: ... uptake Never let your solution climb above 85ºF Hot roots attract pests and diseases as well as significantly reducing oxygen levels and nutrient uptake 8 C The air filter needs cleaning at least once every month The EcoPLus Chiller becomes dirty after being used for extended periods of time Accumulated dirt makes the chiller s exhaustion of heat less effective Simply clean by washing the filter ...

Страница 11: ...with any other appliances DO NOT expose the chiller to direct sunlight or rain DO NOT locate the chiller on a damp floor or area that can be easily flooded or splashed by water or other liquids The socket and cable connector must be able to safely sustain a current 4 to 5 times higher than the normal operating current DO NOT locate chiller near any heat source like a boiler gas stove etc 9 DO NOT ...

Страница 12: ...ating properly or refrigeration stops after a long period of time refrigerant may be necessary Ask a certified and licensed technician to check the chiller for the appropriate amount of refrigerant If refrigerant is low have technician add the proper amount of refrigerant B If air temperature and water temperature are too high the compressor will stop to protect the chiller from over heating C If ...

Отзывы: