Sunjoy Manhattan L-DN2523SST-B-T Скачать руководство пользователя страница 3

3 of 19 

SPECIFICATION 

 

IMPROTANT SAFETY INFORMATION AND PRECAUTION 

  The installation must conform with local codes, or in the absences of local codes with the 

National 

Fuel Gas Code, ANSI Z223.1

/NFPA54;  International  Fuel  Gas  Code,  Natural  Gas  and  Propane 

Installation Code, CSA B149.1; or Propane Storage and Handling Code, B149.2, as applicable.   

  The LP gas supply cylinder to be used must be: 

1-  Constructed and marked in accordance with the U.S. Department of Transportation (D.O.T.)   

Specifications for LP-Gas Cylinders, or the Standard for Cylinders, Spheres and Tubes for 
transportation of Dangerous Goods and Commission, CAN/CSA-B339 as applicable; 

2-  Provided with a listed overfilling prevention device; 
3-  Provided with a cylinder connection device compatible with the connection for the appliance. 

  Always place the appliance on a firm and level surface.   

  Solid fuels shall not be burned in this gas appliance. When using decorative Lava Rocks, use only 

Lava Rocks (INCLUDED). 

  The appliance shall be used only outdoors in a well-ventilated space and shall not be used in a 

building, garage or any other enclosed area. 

  When  in  use,  keep  the  appliance  area  clear  and  at  least  40  in  /  101.6  cm  side, back and top 

clearance from combustible materials, gasoline and other flammable liquid and vapors. Do not use 
the appliance under overhead combustible surfaces. Certain items or materials, when stored under 
the appliance or nearby, will be subjected to radiant heat and could be damaged.

 

 

  Open the door and inspect the hose assembly and burner prior to each use. If there is evidence of 

excessive abrasion or wear or if the hose or burner is damaged, it must be replaced by appropriate 
part from the manufacturer. 

  Inspect the gas connections of the appliance prior to each use. Do not to operate the unit if there is a 

gas leak. Have the appliance inspected annually by a qualified service person.   

Product name

 

Manhattan Fire Pit Table 

Model NO. 

L-DN2523SST-B-T 

Rated Heat Output 

35,000BTU/HR     

Fuel 

Propane-LP 

Gas Supply 

20 lb. LP-Gas cylinder   

 

 

 

 

 

Manifold Pressure 

11 Inches W.C. 

Orifice Size (diameter) 

1.9mm   

 

 

Gas Supply Pressure 

Max.250 PSI                Min.25 PSI 

Содержание Manhattan L-DN2523SST-B-T

Страница 1: ...the appliance CONSUMER Retain this manual for future reference WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury...

Страница 2: ...property damage or personal injury WARNING This product can expose you to Carbon Monoxide which is known to the State of California to cause birth defects or other reproductive harm For more informati...

Страница 3: ...UDED The appliance shall be used only outdoors in a well ventilated space and shall not be used in a building garage or any other enclosed area When in use keep the appliance area clear and at least 4...

Страница 4: ...LP gas cylinders of the U S Department of Transportation DOT The cylinder supplies system must be arranged for vapor withdrawal and the cylinder must include a collar to protect the cylinder valve Use...

Страница 5: ...5 of 19 EXPANDED VIEW...

Страница 6: ...20723A01189 Lid 1 C P31351A01189 Table top 1 D P22003A01178 Fire bowl 1 E P21234A01108 Back panel 1 F P21153A01108 Side panel 1 1 F1 P21165A01108 Side panel 2 1 G P20928A01108 Door 1 H P20814A01108 Ta...

Страница 7: ...Add Part Image AA H02015C11 Bolt M6 15 20 2 BB H02030C11 Bolt M6 30 2 1 CC H09010A11 Bolt M4 10 1 1 DD H19001C11 Flat washer M6 22 3 EE H00001C12 Wrench M6 1 0 If you want to replace the parts listed...

Страница 8: ...8 of 19 INSTALLATION 1 1x 8x 8x 4x 1x 1x 4x...

Страница 9: ...9 of 19 2 2x 2x 1x 1x 4x 2x 2x...

Страница 10: ...10 of 19 3 4x 4x 1x 4x...

Страница 11: ...11 of 19 4 2x 2x 1x 1x 2x...

Страница 12: ...12 of 19 5 4x 4x 4x...

Страница 13: ...13 of 19 1 6 1x 1x 1x 1x...

Страница 14: ...14 of 19 7 1x...

Страница 15: ...venting 2 Open the gas door and put the cylinder inside Gas Connection 1 Open the door and control valve outside See Fig 4 2 Put the cylinder into the cylinder rack See Fig 5 3 Connect the regulator a...

Страница 16: ...ubbles form In case of leaks turn off the gas supply undo the leaking connection re connect it and try again If the leak persists consult Customer Service Center for assistance 1 866 578 6569 5 If the...

Страница 17: ...building garage or any other closed area The fireplace may be stored indoors only if the cylinder is disconnected and removed Keep the fireplace area clear and free from combustible materials gasoline...

Страница 18: ...can be repaired or replaced at the discretion of the manufacturer at no cost to the original purchaser This warranty will be void if the product has not been assembled installed or operated according...

Страница 19: ...w these instructions when in use of the fire pit table 1 Follow the product s instruction manual 2 Set up the fire pit table in a safe distance away from any combustible materials 3 Use the protective...

Отзывы: