Sungrow PVM1000 Скачать руководство пользователя страница 14

10

N

No

o..

N

Na

am

me

e

A

Adjusting screw

B

Supporting foot

C

Steering caster

M

Mo

ovviin

ng

g P

PV

VM

M1

10

00

00

0

When the PVM1000 needs to be moved, you can push the cabinet to move after rotat-

ing the adjusting screws clockwise and folding up the supporting feet.

P

Po

ossiittiio

on

niin

ng

g P

PV

VM

M1

10

00

00

0

After moving PVM1000 to the target position, rotate the adjusting screws counterclock-

wise, and unfold the supporting feet to support PVM1000 cabinet.

4 Mechanical installation

User Manual

Содержание PVM1000

Страница 1: ...riin ng g C Ca ab biin ne et tU Us se er r M Ma an nu ua allP PV VM M1 10 00 00 0 U UE EN N V Ve er r1 10 0 2 20 02 20 00 05 5 PVM1000 UEN Ver10 202005 PVM1000 P PV V M Mo on niit to or riin ng g C Ca...

Страница 2: ......

Страница 3: ...installation 8 4 1 Scope of supply 8 4 2 Storage 8 4 3 Requirements for installation environment 9 4 4 Installation method 9 5 Electrical connections 11 5 1 Internal layout 11 5 2 Preparation before w...

Страница 4: ......

Страница 5: ...that relevant persons can easily get access to them The manual will be continuously updated and revised but it is inevitable that there may be minor discrepancies with the real products or errors The...

Страница 6: ...the contents and may also provide skills or tips for optimizing the use of the product and help the user solve a problem or save time Please pay attention to the danger and warning signs on the produc...

Страница 7: ...ice life of PVM1000 B Be ef fo or re e iin ns st ta alllla at tiio on n When receiving the product please first check whether PVM1000 was dam aged during transportation If you find any problems please...

Страница 8: ...and maintaining the equipment or replacing modules by themselves If users request for repair maintenance or module re placement analysis and confirmation by Sungrow Power Supply Co Ltd are required I...

Страница 9: ...of communi cation PVM1000 is suitable for distributed power stations ground PV power stations energy storage power stations etc C Co om mm mu un niic ca at tiio on n s sc ch he em ma at tiic c d diia...

Страница 10: ...rters etc Integrated with fiber optic switch to enable flexible and convenient networking Simple and efficient Single PV monitoring cabinet can be applied to a 100 MW power station Seamless access to...

Страница 11: ...7 3 3 Overall dimensions Unit mm User Manual 3 Product description...

Страница 12: ...d Pay attention to the following matters when storing Restore the package to the state it was in when it was delivered Retain the desiccant in the package Pay attention to ventilation and moisture pre...

Страница 13: ...ion It should be installed in a dry well ventilated and dustproof place In order to facilitate heat dissipation and daily maintenance sufficient space should be reserved around PVM1000 Unit in figure...

Страница 14: ...ou can push the cabinet to move after rotat ing the adjusting screws clockwise and folding up the supporting feet P Po os siit tiio on niin ng g P PV VM M1 10 00 00 0 After moving PVM1000 to the targe...

Страница 15: ...inet are shown in the following figure The figure above is indicative only N No o P Po or rt t t ty yp pe e A Switch 2 B Switch 1 C Firewall D KVM control platform E Server 2 F Server 1 G Q1 miniature...

Страница 16: ...ed 5 3 Electrical wiring 5 3 1 Grounding connection There are three grounding methods for the PVM1000 cabinet Grounding terminal block grounding point and grounding copper bar 5 3 1 1 Connection by Gr...

Страница 17: ...d du uc ct tiio on n Four grounding points are reserved inside the PVM1000 cabinet and the positions are shown in the following figure Before the combiner box leaves the factory M6 grounding screws an...

Страница 18: ...tiio on n Grounding copper bars are reserved inside the PVM1000 cabinet and their positions are shown in the following figure W Wiir riin ng g r re eq qu uiir re em me en nt ts s Unscrew the screws a...

Страница 19: ...When connecting to a M5 grounding hole the recommended fixing method is as shown in the following figure on the right and the tightening torque is 4 4 8N m N No o N Na am me e A Screw assembly B Groun...

Страница 20: ...on switch 2 to external switch step 3 It is recommended to use CAT 5e cables to connect the Ethernet ports on firewall to ex ternal network devices E En nd d 5 3 3 Connection to external power supply...

Страница 21: ...N of exter nal power supply 4mm2 W Wiir riin ng g s st te ep ps s step 1 Draw the external power supply cable through the inlet hole at the bottom of the cabinet step 2 Peel off the protective layer...

Страница 22: ...in the following figure W Wiir riin ng g r re eq qu uiir re em me en nt ts s 4mm2 power cables are recommended W Wiir riin ng g s st te ep ps s step 1 Peel off the protective layer and insulating laye...

Страница 23: ...Ma aiin nt te en na an nc ce e iit te em ms s a an nd d iin nt te er rv va alls s It is recommended to check every six months Check the heat dissipation channel at the top of PVM1000 cabinet Check the...

Страница 24: ...r ro on nm me en nt ta all p pa ar ra am me et te er rs s Ambient temperature 10 35 server Ambient humidity 0 95 25 C Co om mm mu un niic ca at tiio on n Communication medium Optical fiber Ethernet Ne...

Страница 25: ...rsh environment that does not meet the requirements of this manual Failure or damage to the equipment is caused by installation repair alteration or dis assembly by persons other than those from the C...

Страница 26: ...ea com I In nd diia a Sungrow India Private Limited Gurgaon 91 080 41201350 service in sungrowpower com I It ta ally y Sungrow Italy Verona 39 0800 974739 Residential 39 045 4752117 Others service sun...

Страница 27: ...ungrow emea com U U S S A A M Me ex xiic co o Sungrow USA Corporation Phoenix 1 833 747 6937 techsupport sungrow na com V Viie et tn na am m Sungrow Vietnam Hanoi 84 918 402 140 service vn sungrowpowe...

Отзывы: