9
10
two screws on balance rotating arm.
8.2 Vertical adjustment
After 8.1 finished, power on(make sure arm installed), after system
started, press ‘UP’ button to check the vertical position. If not, please
follow menu settings to adjust DP10. For example, barrier arm not full
90 degrees open, increase the value of DP10. If open more than 90
degrees, decrease the value of DP10 too, setting details please refer to
appendix VI.
9.
Working Codes meanings and error code solutions
9.1. When power-on, press “UP” or “DOWN” button, there is no
reaction on the boom.
9.1.1. Check up the power supply and the fuse.
9.1.2. Check if the remote controller matches the radio receiver; or check
up the battery inside and then change it if it is lack of power.
9.1.3. Check whether there is co-channel interference, and press the
buttons on the control board to check if can work.
9.1.4. Check up if the external protection circuit is failure or in
protection status. Check up the condition of photocell and loop detector are
lighting.
9.2. The barrier gate closes half, and then stop learning, during
controller self-test after power-on.
9.2.1. Check up if the boom is installed, the barrier gate need to work
with boom if springs installed.
10.Warranty and Service Items
10.1. Free service is offered for component parts in one year warranty
time.(not includes the barrier boom and remotes)
10.2. Lifetime service with charge accordingly.
10.3. Technical questions are supported.
10.4. The below items and situations are not included in the range of
free service:
10.4.1. The user does not follow the instruction and cause any damage of
the product.
10.4.2. The power supply is not stable, over the range of permitted
voltage or not accordant to safety electric using standard.
10.4.3. The user installs or uses the product in wrong methods, cause
damage to the appearance of product.
10.4.4. Natural disaster causes damage to the product.
10.4.5. Warranty time is over.
10.4.6. Service items are out of our promises.
11. Maintenance
11.1. Keep the barrier gate clean.
11.2. Check the joints ever month in case of any loose parts.
11.3. Check the balance status of spring after the barrier gate running 1
million times; change new springs after running 3 million times, to avoid
spring breaking due to excessive fatigue.
11.4. Check the easily worn-out parts every half year and renew it.
11.5. Remote control distance will be shortened or not work in cases like
big object screening, battery exhausting, extreme weathers.
12. Packing List
Name
Specification Quantity
Unit
Application
Screws, Nuts, Flat
Pad
M12*70
2
sets
Fixing the boom
Boom Fixing Bar
1
pcs
Fixing the boom
Cabinet Fixing Bar
2
pcs
Fixing the cabinet
Expansion Screws
M14*150
4
sets
Fixing the cabinet
Support Post
1
pcs
Optional
Radio Emitter
1
pcs
Optional
Keys
2
pcs
For cabinet door
Remote Controller
2
pcs
Manual
1
pcs
Appendix I. Table of Spring Selection and
Suggested Max Speed with Boom Length
This mechanism comes standard with 1 pcs 3.5mm and 1pcs 4.5mm
springs. If the standard springs don't meet the actual boom length
requirement, please replace or add the corresponding spring.