Instruction of SR91 Split Pressurized Solar Hot Water System
Page 35 of 49
AHO
40
℃
0.0-95
℃
0.5
℃
Switch-on temperature
AHF
45
℃
0.0-94.5
℃
0.5
℃
Switch-off temperature
t A1O
00:00
00:00-23:
59
Start time of the first time section
t A1F
23:59
00:00-23:
59
Close time of the first time section
t A2O
00:00
00:00-23:
59
Start time of the second time section
t A2F
00:00
00:00-23:
59
Close time of the second time
section
t A3O
00:00
00:00-23:
59
Start time of the third time section
t A3F
00:00
00:00-23:
59
Close time of the third time section
BEEP
OFF
ON/OFF
Beeper warning function ( sensor
fault, no flow)
Function Setting
TIME (Timer function) Setting
►Select AUX main menu, press “SET”, to access TIME submenu
►Press “SET”, “TIME OFF” displays on the screen
►Press “SET”, “OFF” blinks
►Press “+/-”, to activate this function, “TIME ON” displays
►Press “SET” or “ESC” to save the setting
►Press “+”, “t1O 00:00” displays on the screen
►Press “SET”, hour “00” blinks
►Press “+/-”, to adjust hour of the start time of the first section
►Press “SET”, minute “00” blinks
►Press “+/-”, to adjust minute of the start time of the first section
►Press “SET” or “ESC” to save the setting
►Press “+”, “t1F 00:00” displays on the screen
►Press “SET”, hour “00” blinks
►Press “+/-”, to adjust the hour of the close time of the first time section