Instruction of SR81 Split Pressurized Solar Hot Water System
Page 41 of 59
►Press “SET”, “OFF” blinks
►Press “+/-”, to activate this function, “AH ON” displays on the screen
►Press “SET” or “ESC” to save the setting
►Press “+”, “AHS S3” displays on the screen
►Press “SET”,”S3” blinks
►Press “+/-”, to select the object sensor for thermostat function
►Press “SET” or “ESC” to save the setting
►Press “+”, “AHO 40
o
C” displays
►Press “SET”, “40
o
C” blinks
►Press “+/-”, to adjust the switch-on temperature
►Press “SET” or “ESC” to save the setting
►Press “+”, “AHF 45
o
C”displays
►Press “SET”, “45
o
C” blinks
►Press “+/-”, to adjust the switch-off temperature of thermostat function
►Press “SET” or “ESC” to save the setting
►Press “+”, “tA1O 00:00” displays
►Press “SET”, hour “00” blinks
►Press “+/-”, to adjust the hour of start time of the first time section
►Press “SET”, minute “00” blinks
►Press “+/-”, to adjust the minute of start time of the first time section
►Press “SET” or “ESC” to save the setting
►Press “+”,”tA1F 23:59” displays on the screen
►Press “SET”, “23” blinks
► Press “+/-”, to adjust the hour of close time of the first time section
►Press “SET”, “59” blinks
► Press “+/-”, to adjust the minute of close time of the first time section
►Press “SET” or “ESC” to save the setting
►Press “+”, access the setting of the second time section, repeat above steps to set time of
second and third sections.
If you want to close the thermostat function for one section, just set a same time for the start
and close time (e.g. 10:00 start, 10:00 close)
BEEP
(
Beeper warning function
)
setting
►Select BEEP submenu, “BEEP” displays on the screen