Bi-spectrum network camera
User Manual
Thermal Sensor Configuration
Issue V 1.1
(
2022-05-07
)
67
Figure 5-7
FFC control interface
Table 5-1 lists the parameters on the FFC control interface.
Table 5-1
Parameters on the FFC control interface
Parameter
Description
Setting
FFC Mode
The internal of the thermal imaging camera may
comprise the mechanical action correction
mechanism that can periodically improve the
image quality. This component is called flat field
correction (FFC). When controlling the FFC, the
FFC shields the sensor array, so that each portion
of the sensor can collect uniform temperature
fields (flat field). By means of FFC, the camera
can update the correction coefficients to output
more uniform images. Throughout the FFC
process, the video image is frozen for two
seconds and a static-frame image is displayed.
After the FFC is complete, the image is
automatically recovered. Repeated FFC
[How to set]
Select from the
drop-down list
box.
[Default value]
Auto