Temperature range use
14 ºF - 131 ºF (-10 ºC to +55 ºC) and a relative humidity below
90%.
Weight
Weight without regulator: 2.8 oz (80 g).
Working pressure
58–102 PSI (4–7 bar) measured at the connection to the
regulator.
4. Maintenance
Personnel who are responsible for maintenance of the equip-
ment must be trained and well acquainted with this type of work.
4.1 Cleaning
The SR 307 should be cleaned in the following manner: Use
a piece of soft cloth or a sponge dipped in a solution of water
and dishwashing detergent or the like. Rinse and leave to dry.
Sundström cleaning wipes 5226 can be used to advantage
for cleaning.
For particulars of cleaning of the Sundström half mask and full
mask, see the appropriate user instructions.
4.2 Storage
After cleaning, store the equipment in a dry and clean place at
room temperature. Avoid direct sunlight.
4.3 Maintenance schedule
The schedule below shows the minimum requirements on
maintenance routines to assure the user that the equipment
will always be in usable condition.
Before
After
After two
use
use
years
Visual inspection
•
•
•
Functional check
•
•
Cleaning
•
4.4 Spare parts
Use only genuine Sundström parts. Don’t modify the equip-
ment. The use of ’pirate parts’ or any modifications made to the
equipment may reduce the protective effect and compromise
the approvals granted to the equipment.
4.4.1 Regulator
The regulator is a complete, sealed unit. Don’t attempt to
repair or modify it.
4.4.2 Breathing hose
To change the breathing hose, proceed as follows:
• Cut off the hose clip with a pair of pincers and pull the hose
off. Fig. 5.
• Thread the hose clip and retaining clip (Fig. 1:11) onto the new
hose. Connect to the compressed air attachment (Fig.1:2)
and use a pair of pincers to nip the hose clip. Fig. 6.
• Apply a load to the hose to check that it is firmly secured to
the compressed air attachment.
5. List of parts
The item numbers below refer to Fig. 1 at the end of the user
instructions. Parts marked with an asterisk (*) are not shown.
5.1 Spare parts
Item Part
Order No.
1
Breathing hose
R03-1428
2
Compressed air attachment
R03-1425
3 Belt
R03-1510
4
Flow meter
R03-0346
5
Regulator assembly SR 347
R03-1421
*
Service kit
R03-1417
6
Locking ring
-
7
Protective cover
-
8 Membrane
-
9 Silencer
-
5.2 Accessories
Item Part
Order No.
*
SR 358 plastic hose. See section 3
*
SR 359 rubber hose. See section 3
*
Cleaning tissues, box of 50
H09-0401
*
Cleaning tissues, box of 1,000
H09-0402