14
6. Inspection
Check that the aluminum bag not has been damaged so that the
vacuum has been lost. The aluminum bag shall fit tight around
the escape hood. Fig 7.
1) Check the aluminum bag visually. Fig. 8.
If it is not possible to decide visually, proceed to step 2.
2) Gently pull the aluminum bag. Fig. 9.
Model M should be examined without lifting the bag from the
nylon emergency bag.
In case of uncertainty - recheck the aluminum bag on a calibrated
scale. The weight may not be increased more than maximum
2.0 grams compared to the starting weight standing on the
aluminum bag.
Clamped,
exposed for
blows or shocks
Before each
work shift
Every
3rd month
Model M
•
•
Model S
•
•
NOTE!
When the escape hood has been clamped or exposed
for blows or shocks, the check shall be performed first 8 hours
after damage.
7. Shelf life
Temperature
Relative humidity
Shelf life
-20 - +55 °C
< 90 %
10 year
8. Approvals
SR 76-3
Chem
have been tested and approved in two variants in
accordance with EN 403:2004 with the exception of Clause 6.11
Filter:
•
SR 76-3 S which is intended for stationary storage.
•
SR 76-3 M which is also approved as a portable escape hood.
The filters of the hood have been tested and approved inaccord-
ance with EN 14387 (gas filter) and EN 143:2000 (particle filter). SR
76-3 Chem is CE labelled.
SR 77-3
Smoke
have been tested and approved in two variants in
accordance with EN 403:2004 and EN 14387:
•
SR 77-3 S which is intended for stationary storage.
•
SR 77-3 M which is also approved as a portable escape hood.
SR 77-3 Smoke is CE labelled.
The EC type approval certificates have been issued by Notified-
Body No. 0194. For address, see back-cover.
Australian StandardsMark
The escape hoods SR 76-3 and SR 77-3 are tested and certified
to comply to AS/NZS 1716:2012. For advice, see also AS/NZS
1715:2009 Use and Maintenance of Respiratory Equipment.
The StandardsMark is issued under licence by SAI Global
Certification Services Pty Limited Lic No.766 (ACN 108 716
669) (“SAI Global”).
9. Label symbols
See user instruction
Production date
Use-by date
+55 °C
-20 °C
Max. ambient relative humidity
during operation and storage
Temperature range
during operation and storage
Handle with care
Vacuum
No vacuum
Do not clamp
Do not drop
Do not step
Keep dry
Содержание SR 76-3 Chem
Страница 47: ...47 1 2 3 5 4 6 HANDLE WITH CARE ...
Страница 48: ...48 7 9 8 ...
Страница 49: ...Vacuum check Date Result Sign Date Result Sign ...
Страница 50: ...Vacuum check Date Result Sign Date Result Sign ...
Страница 51: ......