Sundstrom SR 100 Скачать руководство пользователя страница 9

4. Fit check

2020-03-06

OI01H-2018 SR 100

9

4.1

Place the pre-filter holder 

to the filter.

4.2

Put the mask on.

4.3

Place the palm of your 

hand lightly over the hole on 
the pre-filter holder to make it 
tight. 

NOTE! 
Do not push so hard that the 
respirator

´s shape is affected.

Take a deep breath and hold 
your breath for about 10 s. 
If the mask is tight, it will be 
pressed against your face. If 
any leakage is detected, 
check the inhalation and 
exhalation valves, adjust the 
straps of head harness or 
switch to alternative size of 
the respirator. Repeat the fit 
check until there is no 
leakage.

Содержание SR 100

Страница 1: ...2020 03 06 OI01H 2018 SR 100 1 Operation instructions SR 100 Half mask Revision 03...

Страница 2: ...hen serves as a breathing apparatus with continuous flow for connection to a compressed air supply A wide range of accessories are available When selecting equipment for SR 100 some of the factors tha...

Страница 3: ...Unpacking the SR 100 Packing list Half mask Pre filter holder Cleaning tissue ID tag Pre filter Storage bag Instruction for use 2020 03 06 OI01H 2018 SR 100 3...

Страница 4: ...rd until you hear the particle filter snap onto the gas filter 1 3 Check that you have selected the right filter and that the use by date has not been passed Specified on the filter and is valid provi...

Страница 5: ...ter in the mask so that the arrows on the filter point towards the user s face Carefully check that the edge of the filter is in the internal groove of the filter mounting all around 1 6 Fit pre filte...

Страница 6: ...k in one hand grab the strap buckle and pull on the head strap until the pad is tight against the mask 2 2 Take out any twists or tangles 2 3 Holding the strap buckle pull the strap over your head and...

Страница 7: ...nning 2020 03 06 OI01H 2018 SR 100 7 2 5 Grab the pad with one hand and the filter with the other 2 6 Hold the mask against your face 2 7 Pull the pad over your head and place it on the crown of the h...

Страница 8: ...free end of the harness strap 3 2 Pull the free end away from the neck until buckle pops open 3 3 Pull on the free end of the strap until the respirator seats comfortably on your face Use your thumb...

Страница 9: ...make it tight NOTE Do not push so hard that the respirator s shape is affected Take a deep breath and hold your breath for about 10 s If the mask is tight it will be pressed against your face If any l...

Страница 10: ...membrane 5 2 Check the edge of the inhalation valve Gently stretch the flap until it slips over the stud 6 1 Detach the head harness by pushing the two connection points towards the filter attachment...

Страница 11: ...vers off the membrane seats 7 2 Prise off the membranes 7 3 Press the new membranes onto the dowels Carefully check that the membranes are in contact with the membrane seats all round 7 4 Press the va...

Страница 12: ...ch must have clean and undamaged contact surfaces Inspect all parts and replace with new parts as necessary Leave the mask to dry and then assemble it Sundstr m cleaning tissues SR 5226 are recommende...

Страница 13: ...9 Maintenance schedule 2020 03 06 OI01H 2018 SR 100 13 Before use After use Annually Visual inspection Functional check Cleaning Membrane change Head harness change...

Отзывы: