SunDanzer DCRF450 Скачать руководство пользователя страница 4

 

Generic Compressor Electronics Diagram 

 

 

 

 

 

Low Voltage Disconnect  (LVD) 

The compressor electronics includes a low voltage disconnect.  This feature is designed to 
protect the battery.   Contact SunDanzer if other LVD limits are required. 
 

 

12V 

Operation 

 

24V 

Operation 

 

Cut-in 

 

10.9V  

22.7V  

Cut-out 

 

9.6V  

21.3V  

 

OPERATION   

 

Starting the Appliance  

If the refrigerator has been transported on its side, allow 3 hours before applying power.  This 
provides time for any oil trapped in the cylinder to settle back into the oil sump.  Once ready, 
connect the 12 or 24 VDC power source and the refrigerator will automatically turn on within 
about 1 minute.   The freezer compartment will cool first and reach below freezing temperature 
within  1  hour.    The  refrigerator  (fresh  food)  compartment  might  take  up  to  4  hours  to  reach 
proper temperature, depending on ambient conditions.  The refrigerator might cycle on and off 
during this initial cool down period, this is normal. 
 

Temperature Control 

 

The  temperature  is  automatically  controlled  by  a  digital  thermostat.    No  user  adjustment  is 
necessary or possible.  The refrigerator will automatically maintain temperature within the limits 
in  the  table  below  as  long  as  the  ambient  temperature  is  between  60  &  90F  (16  &  32C). 
Insertions of large warm food loads will temporarily result in higher temperatures. 