13.0  Spa Equipment Packs

13.1  Solo Equipment Pack

1.

Overflow Fitting

2.

Drain Cap

3.

Auxiliary Pan Drain
Location

4.

Load Box

5.

Safety Screen
and Heater Intake

6.

Drain Valve

7.

Heater

8.

Circulation Pump

9.

Main Pump

10. Filter
11. Pan
12. Wood Frame
13. Pump Unions

3

2

8

11

7

10

1

5

6

13

4

12

9

13.2  Metro Equipment Pack

1.

Load Box

2.

Heater

3.

Circulation Pump

4.

Main Pump

5.

Pump Unions

1

4

5

2

3

28

Содержание Portofino Caprio

Страница 1: ...Portofino Series Installation Owner s Manual Portofino Series Installation Owner s Manual...

Страница 2: ...use the larger pleated filter car tridge every month See page 17 18 for detailed filter cleaning replace ment instructions Water Maintenance You will want to replace the spa s water every 3 to 6 month...

Страница 3: ...als 10 8 0 Control Panel Functions 11 9 0 Operating Instructions 12 9 1 Setting Water Temperature 12 9 2 Pump Button 12 9 3 Light Button 12 9 4 Solo Massage Selector Air Control Operation 13 9 5 Metro...

Страница 4: ...ICE 26 11 8 Panel displays 26 12 0 Troubleshooting Procedures 26 12 1 No Components Operate e g Pump Light 26 12 2 Pump Does Not Operate But Light Does 26 12 3 Poor Jet Action 27 12 4 Water is Too Hot...

Страница 5: ...tions illustrations and or instructions contained herein 2 0 FCC Notice This equipment has been tested and found to comply with the limits for a Class B Digital Device pursuant to Part 15 of the FCC R...

Страница 6: ...cal compo nents 5 CAUTION 240 VAC POWERED SPAS These spas must be hard wired to your household electrical service box only Do not use an extension cord or any other disconnectable power cord The use o...

Страница 7: ...F 38 C and 104 F 40 C are considered safe for a healthy adult Lower water temperatures are recommended for extended use exceeding 10 15 minutes and for young children 15 Since excessive water temperat...

Страница 8: ...ino spa is equipped with the state of the art LX 10 equipment system It contains the most advanced safety and self protective equipment in the industry Nonetheless this spa must be installed properly...

Страница 9: ...nd other casual water to flood the equipment and create a wet condition in which it would sit For spas which will be recessed into a floor or deck install so as to permit access to the equipment eithe...

Страница 10: ...nces or lights sharing the power provided by the circuit 5 0 Power Supply Requirements All US Canada 120 240 VAC Convertible Models 60 Hz 120 VAC 240 VAC 240 VAC 15 A 30 A 40 A Voltage 120 VAC 240 VAC...

Страница 11: ...will not operate at the same time as the main jets pump This is the factory setting In the 30 A configuration the heater will operate at the same time as the main jets pump Important Information The...

Страница 12: ...el on the light side of the spa Then remove the faceplate from the load box Refer to sections 13 1 13 3 page 28 29 for your specific spas load box location 4 Locate the hole in the cabinet above the p...

Страница 13: ...r For more information consult your dealer prior to filling it Only spas with a smooth acrylic surface require waxing It is not necessary to wax spas with the textured Quarite surface Remove the filte...

Страница 14: ...unions to make sure they are hand tight Refer to sections 13 1 13 3 page 28 29 Loosening can occur during shipping and handling Solo models only turn the drain valve off Refer to section 13 1 page 28...

Страница 15: ...n turns jets on and off Press once for low speed press a second time for high speed press a third time to turn off Operation Details Temperature Adjustment 65 to 104 F 18 to 40 C Software default sett...

Страница 16: ...ing Then the heater turns off and the circulation pump remains on for 24 hour operation Note it is common for the heater to turn on after the spa is first filled because tap water is often very cold 9...

Страница 17: ...t Group C and Jets A B Air Controls Functions Air Controls A C Open An Air Venturi to Specified Jets Jets A Jets B Jet Group C A B Z C A A A A Z B B B B C C 13 Air Controls Functions Air Controls A B...

Страница 18: ...B C Are Always On However The Jet Faces of These Jets Can be Adjusted to Personal Preference Levels Air Controls Functions Air Controls A C Open An Air Venturi to Specified Jets Jet Group A Jet Group...

Страница 19: ...below for additional information 9 8 Standard Skimming Heating Modes F0 F3 Standard skimming heating modes are typically selected by custom ers in cold climates where heatup times are extended due to...

Страница 20: ...0 minute cycle every 6 hours Economy Skimming Heating Modes F4 1 hour of skimming heating per day one 30 minute cycle every twelve hours F5 1 5 hours of skimming heating per day one 30 minute cycle ev...

Страница 21: ...by the main 2 speed pump drawing water through the larger side of the cartridge during normal operation and during each skimming heating cycle Combined both halves work together to give you clean wate...

Страница 22: ...Insert retainer into stage 2 filter and rotate clockwise to assembly DO NOT overtighten retainer finger tight only G 1 Install filter assembly then tighten filter nut so it just touches filter face D...

Страница 23: ...xpectancy of the polyester mesh filter cartridge is approximately two years with proper care and water quality maintenance The smaller stage 2 filter cannot be cleaned and must be replaced thrown out...

Страница 24: ...your authorized Portofino dealer Regardless of the cleanser used use extreme care to assure that no soap residue is left on the surface This could cause foaming when the spa is refilled 10 4 Cleaning...

Страница 25: ...od preservative will enhance and protect the richness of the wood A specially formulated wood stain available from your Sundance dealer is ideal for this job Note Do not apply varnish shellac or other...

Страница 26: ...r authorized Portofino dealer who can recommend appropriate chemical products for sanitizing and balancing your spa water CAUTION Never store spa chemicals inside the spa s equipment bay 10 10 Control...

Страница 27: ...e an extremely corrosive effect on certain materials in the spa Damage caused by use of this chemical or improper use of any chemicals is not covered under the manufacturer s warranty Many other addit...

Страница 28: ...roximately 2 F 1 C above the set temperature the circula tion pump will stop operating to reduce frictional heating If the spa water temperature continues to rise and gets above 112 F 44 C the spa wil...

Страница 29: ...To Correct Condition 1 Remove filter and allow air to bleed out of cartridge 2 Check for proper water level 3 Check for clogged excessively dirty filter cartridge 4 Check secondary screen filter Solo...

Страница 30: ...riate troubleshooting instructions Note If any of the supply cords to the accessories are damaged they must be replaced by authorized service personal 12 1 No Components Operate e g Pump Light Check t...

Страница 31: ...12 5 No Heat 1 Check thermostat setting 2 Keep the spa cover in place while heating Your authorized dealer is a trained service repair center Should checking the above steps fail to correct the proble...

Страница 32: ...n Drain Location 4 Load Box 5 Safety Screen and Heater Intake 6 Drain Valve 7 Heater 8 Circulation Pump 9 Main Pump 10 Filter 11 Pan 12 Wood Frame 13 Pump Unions 3 2 8 11 7 10 1 5 6 13 4 12 9 13 2 Met...

Страница 33: ...Equipment Pack 1 Load Box 2 Heater 3 Circulation Pump 4 Main Pump 5 Pump Unions 1 4 2 5 3 1 Overflow 2 Control Panel 3 Air Controls 4 Massage Selector 5 Skimmer Weir 6 Filter 7 Neck Jets 8 Filter Nut...

Страница 34: ...ir Controls 3 Massage Selector 4 Filters 5 Neck Jets 6 Skimmer Weir 7 Filter Nut 8 Safety Screen Located Inside Filter Wall Fitting 213 cm 84 163 cm 64 1 2 2 3 5 7 8 Equipment Access Door Do Not Obstr...

Страница 35: ...Remove and discard the factory installed GFCI Cord 2 Move RED wire from TB1 position 1 to TB1 position 3 as shown below 3 Permanently connect to the power supply Use copper conductors ONLY Wire size...

Страница 36: ...or Temperature Sensor J2 J3 F1 20A 250V SC 20 Circ Pump Main Pump Spa Light Transformer 230 VAC J4 HI LO GRN Export 230 VAC 50 Hz Power Connections Logic Jumper Settings All Models JP1 1 2 ON 20A Logi...

Страница 37: ...ut Programmable Temperature Filtration and Heat Cycles Water Delivery 1 TheraFloTM High Flow Pump Pump 1 Rating US Canada Convertible Model 60 Hz 2 Speed 1 5 hp Continuous 13 6 A Max Export Models 50...

Страница 38: ...lt on Optional Blue or Camel Insert Heater US Canada Convertible Model 60 Hz Low Flow 1 kW 120 VAC or 4 kW 240 VAC Export Models 50 60 Hz Low Flow 2 7 kW Electrical Requirements USA Canada Convertible...

Страница 39: ...19 Liters Controls Solid State Electronic Controls with LED Readout Programmable Temperature Filtration and Heat Cycles Water Delivery 1 TheraFloTM High Flow Pump Pump 1 Rating US Canada Convertible M...

Страница 40: ...s Integral Pillows 2 Part 2 Tone Gray Bolt on Optional Blue or Camel Insert Heater US Canada Convertible Model 60 Hz Low Flow 1 kW 120 VAC or 4 kW 240 VAC Export Models 50 60 Hz Low Flow 2 7 kW Electr...

Страница 41: ...olid State Electronic Controls with LED Readout Programmable Temperature Filtration and Heat Cycles Water Delivery 1 TheraFloTM High Flow Pump Pump 1 Rating by Model US Canada Convertible Model 60 Hz...

Страница 42: ...1 Integral Pillows 2 Part 2 Tone Gray Bolt on Optional Blue or Camel Insert Heater US Canada Convertible Model 60 Hz Low Flow 1 kW 120 VAC or 4 kW 240 VAC Export Model 50 Hz 60 Hz Low Flow 2 7 kW 230...

Страница 43: ...Notes...

Страница 44: ...Sundance Spas Inc 14525 Monte Vista Ave Chino CA 91710 U S A Phone 909 606 7733 Fax 909 606 0195 Website http www sundancespas com 6530 386 Rev A 2003 Sundance Spas Inc Printed in U S A...