Page 9
• WARRANTY
: Damage caused by not following these guidelines or
any improper installation not in accordance with local codes or au-
thorities is not covered under the spas warranty. Please consult your
local state or city building ordinances.
WARNINg:
In addition to maintenance of filters and water
chemistry, proper ventilation is recommended to reduce the
risk of exposure to viruses and bacteria that could be present
in the air or water. Consult a licensed architect or building
contractor to determine your specific needs if installing your
spa indoors.
5.0 Power Requirements
Sundance® spas are designed to provide optimum performance and
flexibility of use when connected to the maximum electrical service listed
on page 10-11. Minor circuit board modifications can be performed to
allow your new spa to accept an electrical service other than the factory
50 Amp operation setting.
Note: Refer to pages 34-35 for circuit board
configuration details or contact your authorized Sundance dealer.
All Models (60Hz)
240V/40A*
240V/50A**
240V/60A***
Voltage:
240 VAC
240 VAC
240 VAC
# of Wires:
3
3
3
Frequency:
60Hz
60Hz
60Hz
Current Draw:
26A
36A
45A
Circuit Breaker:
40A, 2-Pole
50A, 2-Pole
60A, 2-Pole
*
In 40A configuration, the heater
will not operate
while either jets
pump is running in high speed.
Note: pump 2 runs only in high
speed.
**
In 50A configuration, the heater
will not operate
while both jets
pumps are running in high speed.
Note: pump 2 runs only in high
speed. This is the factory setting.
***
In
60A configuration, the heater
will operate
while both jets pumps
are running in high speed.
Note: pump 2 runs only in high speed.