Page 48
14.0 Troubleshooting - Display Messages
There are a number of unique functions designed into your Sundance
hot tub to protect it from damage and/or to aid in troubleshooting.
Following is a listing of all the possible messages along with their
meanings:
MESSAGE
MEANING
overheat Protection (Heater is deactivated, cir-
culation pump is activated). Water temperature is
above acceptable limits. Do not enter the water!
Remove hot tub cover to speed cooling. See
“Water is too hot” on page 51. If condition persists,
contact your dealer or authorized service center.
If the hot tub water is more than 20 °F cooler than
the temperature setpoint, jets pump #1 and heater
will automatically activate to provide freeze protec-
tion. The hot tub will stay in this mode until the
water temperature reaches 15 degrees below the
set temperature. No corrective action is necessary.
FLoW SWITCH (Heater is deactivated. The cir-
culation may also be deactivated). Proper flow
of water is inhibited or a flow switch has mal-
functioned. Check for proper water level and for
clogged filter (page 40-41). Contact your dealer or
service organization.
*NoTE: THIS MESSAGE CAN ALSo APPEAR IF THE PuMP HAS
NoT REGAINED PRIME AFTER THE HoT TuB HAS BEEN DRAINED
AND REFILLED. IF You SuSPECT THAT THIS IS THE CASE, SEE
THE INSTRuCTIoNS oN PAGE 50 uNDER “PuMP DoES NoT
oPERATE...”
Panel sensors have been pressed too many times
in a short period of time. Because this could cause
excessive wear on equipment components, panel
sensors are temporarily deactivated. Panel sensors
will automatically re-activate if no sensor is pressed
for 30 seconds.
*
Содержание Cameo 880
Страница 1: ...maxxus optima majesta cameo ...
Страница 30: ...Page 26 9 11 Maxxus Massage Waterfall Selector Diagram ...
Страница 31: ...Page 27 9 12 Maxxus Air Controls Diagram ...
Страница 33: ...Page 29 9 14 Optima Air Controls Diagram ...
Страница 35: ...Page 31 9 16 Cameo Air Controls Diagram ...
Страница 67: ...Page 63 Notes ...
Страница 68: ...Page 64 Notes ...