Plug-In Thermostat™

®

Model DS100

DuctStat

 

OUTLET

SUNCOURT

maximum load

5A at 125Vac

SET POINT

Do not force

A

IR

TE

M P SENSIT

IV

IT

Y

MIN

MAX

SENSITIVITY

DIFFERENTIAL

INSTALLATION NOTES

INSTALLATION INSTRUCTIONS

CONTROL PANEL

In order to prevent excessive strss on the mounting screws support the DuctStat

® 

unit when unplugging connected devices.

DO NOT use the DuctStat

® 

outdoors or in damp locations.  DO NOT use the DuctStat

® 

in an attic or crawl space.

The DuctStat

® 

is intended to control the automatic on/off operation of In-Line Duct Fans™ installed in the ductwork of forced air

distribution systems.
The DuctStat

® 

can also control the line voltage to any electrical device with a maximum current draw of 5 Amperes.

The DuctStat

® 

is equipped with an external, replaceable 5 Amp fuse to protect the electronic circuitry from overload or short circuits.

This unit is equipped with a three-prong grounded plug.  DO NOT attempt to defeat the ground feature of this plug.  Defeating this will
void the warranty.

1.      Locate the position between the In-Line Duct Fan

™ 

and the register where you wish to lo mount the DuctStat

®.

        

Mount between 1 and 10 feet downstream from the In-Line Duct Fan™.

2.      Tape the template supplied with the DuctStat

®

 to the air duct to mark the mounting holes to be drilled.

3.      Drill a hole in the air duct for the Air Intake Hole shown on the template.  This hole should be ½" in diameter.
4.      Drill holes in the air duct to line up with the appropriate holes located on the template.  On round ducts, two screws
         placed through the slots in the DuctStat

® 

unit's base will be adequate (placement shown on template).

         or rectangular ducts use four screws, one at each corner of the DuctStat

®

 (placement shown on template).

5.      Tighten the supplied screws snugly in the appropriate placement fo your ductwork.  DO NOT OVER TIGHTEN.
6.      Wire a grounded power cord to the In-Line Duct Fan™ and plug into the outlet on the face of the DuctStat

® 

unit.

7.      Plug the DuctStat

® 

power cord into a 110 volt grounded household outlet.

8.      Follow Operation/Settings to adjust the DuctStat

® 

unit.

Function switch selections:
OFF to stop operation of the In-Line Duct Fan™
ON for continuous operation of the In-Line Duct Fan™
AUTO HEAT for automatic on/off to boost warm air.
AUTO COOL for automatic on/off to boost cool air.

The rotary Set Point knob selects the automatic on/off
temperature setting for both heating and cooling.

The Sensitivity Differential switch 
provides control over on/off cycling.