2. Preparation to Remove the 
Air Conditioner Slide-Out Chassis

A. Remove total of  (4) Philips screws securing
the chassis to the cabinet. There are (2) screws 
on each side. The set of screws closest to the 
front of the unit secure the front panel to the 
cabinet. The set of screw closest to the rear of 
the unit secure the cabinet to the chassis.

 See (

Fig. 1).

B. Remove the front panel assembly from the 
cabinet by  gently pulling it.

C. Grasp the pull handle at the front of the 
slide-out chassis and carefully slide the 
air conditioner out of the cabinet. See (

Fig. 2).

NOTE: Screws must be reinstalled upon

completion of the window installation to

secure slide-out chassis.

Please seek assistance for this procedure.

Fig. 2

Fig. 1

Right side
Philips screws

Shutter Frame

Right Shutter

1/4" screw

For 10K to 12K models 

Channel

1/4" Screw

Fig. 3

Fig. 4

Installation instructions

3. Assembly of the upper & lower channels to 
the cabinet

A. " L" Shaped Top Channel: Stick the double
adhering seal to the " L" shaped top channel, and
then Install the "L" shaped top channel to the 
cabinet as shown in (

Fig. 3)

 using (5) 1/4" screws.

B. "n" Shaped Bottom Channel installed as
shown in (

Fig. 3

)using (4) 1/4" screws.

NOTE: For 18K to 24K  models, the bottom channel 
has been factory-installed, and their shapes may 
differ from the others, but their functions  are similar. 

4. Assembly of the side shutters
(curtains) to the cabinet.

Slide the shutters into the top and bottom
channels as shown in (

Fig. 4).

 The shutters are 

identified (on each frame) as "left" & "right".  Attach
the shutters to the cabinet using (4) 1/4" screws 
on each side. 

Double 
Adhering seal

 For 18K to 24K models,
   ( Factory-Installed)

F
HR

  FAN
SPEED

MODE

OFF

ON

/

TIMER

Airconditioner

WAIT THREE MINUTES 

BEFORE RESTARTING

Coil

Pull Handle

Chassis

Содержание SCA103RWB1

Страница 1: ...User s Manual 10 000 BTU Room Air Conditioner Model SCA103RWB1 20060316...

Страница 2: ...ontents Introduction Parts Identification Electrical Specifications Tips Before Installation Installation Instructions Operating Instructions Care and Maintenance Troubleshooting Guide Page 2 2 4 5 6...

Страница 3: ...before starting This manual contains information for the installation and operation of your room air conditioner Note The figures in this manual are based on the external view of a standard model Cons...

Страница 4: ...ou have selected Introduction Part Identification Remote control model Remote Control Exterior Air Inlet Power Cord Cabinet Air Outlet Fresh Air Vent Lever Control Panel Front Panel Interior Air Inlet...

Страница 5: ...o the rating plate of your air conditioner Table 1 If the air conditioner has a serial plate rating of 115 volts and up to and including 7 5 amps the unit maybe on a fuse or circuit breaker with other...

Страница 6: ...nstallation operating difficulties read the instructions thoroughly NOTE Save the shipping carton and packing materials for future storage or transport of the unit Please check the contents of the har...

Страница 7: ...for ample air circulation through the unit See Fig B The rear of the unit should be outdoors and not in a garage nor inside of a building Keep unit as far away as possible from obstacles and obstructi...

Страница 8: ...er 1 4 screw For 10K to 12K models Channel 1 4 Screw Fig 3 Fig 4 Installation instructions 3 Assembly of the upper lower channels to the cabinet A L Shaped Top Channel Stick the double adhering seal t...

Страница 9: ...l V slot 2 3 4 screws per bracket Bracket Assembly Leveling Screw Outer Wall Construction 3 16 Maximum B Measure the inside window sill width and find the center as shown in Fig 6 Align the V slot in...

Страница 10: ...ters A Carefully slide the air conditioner back into the cabinet Please seek assistance for this procedure B Reinstall the slide out chassis security screws removed earlier on both sides of the cabine...

Страница 11: ...moval may be excessive enough to overflow the unit or increase the noise of the air conditioner If this occurs you may wish to attach a drain hose not included to the drain plug allowing condensations...

Страница 12: ...air circulation Recommended for night time use HIGH COOL provides cooling automatically with quick cooling or for extremely hot days Once room is cooled reduce setting to LOW COOL NOTE After setting t...

Страница 13: ...remaining time to turn off the unit for only 12 seconds then LED shifts to display set temperature If you press TIMER button within the 12 seconds OFF TIMER will be canceled If the ON TIMER is set the...

Страница 14: ...ontrol 4 High BUTTON Used to select the mode high fan speed 5 Mid BUTTON Used to select the Mid mode fan speed 6 Low BUTTON Used to select the Low mode fan speed 7 Auto BUTTON Used to select the Auto...

Страница 15: ...A 1 5volt batteries Do not use rechargeable batteries Replace batteries with new ones of the same type when the display becomes dim To operate the room air conditioner aim the remote control to the si...

Страница 16: ...e front grill To remove the air filter open the air inlet grille and take the air filter To reinstall the air filter reverse the above procedure DO NOT forget to install the air filter If the air cond...

Страница 17: ...ngle for proper condensation run off Check the unit and make adjustments Formation of mold mildew or algae on wet surfaces Condensation run off is normal during hot and humid weather Add flexible tubi...

Страница 18: ...reserved Sunbeam is a registered trademark of Sunbeam Products Inc used under license Distributed by Petters Consumer Brands LLC 4400 Baker Road Minnetonka MN 55343 For service support and warranty i...

Отзывы: