1. All wiring must comply with local and national
electrical codes and must be installed by a
licensed electrician. Once you have any
questions regarding the following instructions,
contact a licensed electrician.
2. C heck available power supply and resolve any
wiring problems B E F OR E installing and operating
this unit.
3. F or your safety and protection, this unit is
grounded through the power cord when
plugged into a matching wall outlet. If you are
not s ure whether your wall outlet is properly
grounded, pleas e cons ult a licens ed
electrician.
4. T he wall outlet(3-pin) must match the plug
(3-pin) on the power cord supplied with the unit.
DO NOT use plug adapters or extension cords.
S ee (T able 1) for receptacle and fuse information.
5. T he rating plate on the unit contains electrical
and other technical data. T he rating plate is located
on the right side of the unit.
If the air conditioner has a s erial plate rating
of 115 volts and up to and including 7.5 amps
the unit maybe on a fuse or circuit breaker
with other devices . However, the maximum
amps of all devices on that fus e or circuit
breaker can not exceed the amps of the fus e
of circuit breaker.
If the air conditioner has a s erial plate rating
of 115 volts and greater than 7.5 amps it
mus t have its own fus e or circuit breaker,
and no other device or unit should be
operated on the fus e or circuit breaker.
T o avoid the pos s ibility of pers onal injury,
dis connect the power to the unit before
ins talling or s ervicing.
E lec tric S hoc k Hazard
E lectrical s pecifications
125
5K
6K
8K
T able 1
15
15
R ATE D V OLT S
C OOLING C AP ACIT Y
AMP S
F US E S IZE
WALL OUT LE T
R E C E P T A CL E A ND F US E T Y P E S
!
T ime Delay F use
(or circuit breaker)
P lug type
3