CARE OF CABINET

The outside of the cabinet  can  be cleaned by using a
soft,  clean,  damp cloth.  Never  immerse the unit in
w a t e r .

TO REMOVE ELECTRONIC COLLECTING
CELL FOR CLEANING

The Electronic Collecting  Cell  Will  need cleaning
about  every four to eight weeks when your air cleaner

is in constant use.

Turn off the air cleaner and unplug  it trom the  electri-
cal power source.

Remove cabinet lid by depressing tab located under

lid overhang. (See Figure 11 for exact tab placement)

Slide lid forward from base and  lift off. (Figure 4)

Push Cell  Locking Latch  (Figure 5) away from Cell

while lifting  Cell   out  of the cabinet using the two  small

handles on top of the  Cell.  (Figure 5  & Figure 6)

Slide  Pre-Filter  upward from the front of the  Cell  (Fig-
ure 7) and remove.

Slide Charcoal Filter  upward from  back  of the Cell
(Figure 6) and remove.

Figure 4

F i g u r e   5

Figure  8

Figure  7

Figure   5

REPLACEMENT OF CHARCOAL  FILTER

ACTIVATED CHARCOAL  FILTER  HELPS REMOVE

HOUSEHOLD  ODORS

Washing the Charcoal  Filter  with soap and water  Will
destroy its ability to adsorb odor.

Odor adsorption effectiveness  Will  gradually  deterio-
rate and the Charcoal  Filter  should be  replaced  every
three months. These filters are available in your  retail
store or through a reorder form enclosed  with this unit.

2

Содержание 2571

Страница 1: ...w MODEL 2571 OWNER S MANUAL CAUTION READ AND SAVE THESE INSTRUCTIONS 900 AIR CLEANER AND IONIZER OPERATING INSTRUCTIONS Any questions or comments Call I 800 526 2832 Mon Fri 8 a m 4 p m Centrai Time...

Страница 2: ...lly electronically cleaned air passes back into the room through the top grill Figure 1 Figure 1 Figure 2 k LOCATION Remove the plastic bag covering your air cleaner Select the location for your air c...

Страница 3: ...ell Locking Latch Figure 5 away from Cell while lifting Cell out of the cabinet using the two small handles on top of the Cell Figure 5 Figure 6 Slide Pre Filter upward from the front of the Cell Fig...

Страница 4: ...essary Figure 9 Figure 10 Shake as much water out of the cell as possible Replace Cell in the unit as described below and oper ate unit in FAN ONLY position for a minimum of one hour to insure cell is...

Страница 5: ...e top backward until flush with the back of the unit Figure 17 Operate the unit in FAN ONLY position for a min imum of one hour to insure the cell is thoroughly dry NOTE An occasional arcing sound is...

Страница 6: ...replace Clean wall contacts 6 Be sure wall contacts are slightly bent upward and Cell is positioned against contacts Ref Fig 14 Reposition needle towards back wall of unit by pressing front center of...

Страница 7: ...ARTS 1 Key Number Part Number Description 1 344950 001 Cabinet Top 2 342480 001 Pre Filter 3 442415 001 Electronic Collecting cell 4 6571 Charcoal Filter Set of 2 To order Replacement Parts write to A...

Страница 8: ...e Service Station 117 Central Industrial Row Purvis Mississ ippi 39475 for repair or replacement without charge at the manu facturer s option This warranty gives you specific legal rights and you may...

Отзывы: