Quick Setup Instructions

1. Unpack the server, and check that you received all of the shipping contents.

2. Place the server in its intended location for verification.

For rackmounting instructions, refer to the instructions included with the rail kit, the service label on the
server, and to the online

Sun SPARC Enterprise T5120 and T5220 Servers Installation Guide

.

3. Connect a serial cable between the server’s SER MGT port (

FIGURE 2

) and a terminal device.

This connection provides your initial communication with the SP.
The device must be set up to communicate using 9600 baud, 8 bit, no parity, 1 stop bit. A null modem
configuration is needed, meaning the transmit and receive signals are reversed (crossed over) for DTE to
DTE communications. You can use the supplied RJ-45 crossover adapters with a standard RJ-45 cable to
achieve the null modem configuration.

Time Zone

Select the time zone.

Date and Time

Accept the default date and time, or change the values.

root

Password

Enter the

root

password twice. This password is for the superuser account

for the Solaris OS on this server. This password is not the SP password.

TABLE 1

Configuration Information

(Continued)

Содержание T5120

Страница 1: ...first time Do not apply power until instructed to do so This system includes a service processor SP that is used to configure and boot the host server To properly configure the host server and view SP messages do not apply power to the server until the SP and host networking connections are made as described in this guide Choose the best instructions for your situation The quick setup instructions...

Страница 2: ... device Network Select Yes Multiple Network Interfaces Select the network interfaces that you plan to configure If you are not sure select the first one in the list DHCP Select Yes or No according to your network environment Host Name Enter the host name for the server IP Address Enter the IP address for the selected Ethernet interfaces Subnet Select Yes or No according to your network environment...

Страница 3: ...s your initial communication with the SP The device must be set up to communicate using 9600 baud 8 bit no parity 1 stop bit A null modem configuration is needed meaning the transmit and receive signals are reversed crossed over for DTE to DTE communications You can use the supplied RJ 45 crossover adapters with a standard RJ 45 cable to achieve the null modem configuration Time Zone Select the ti...

Страница 4: ...o which the server will communicate 6 Build and connect your DC power cables into the server power supplies and into separate power sources Instructions for building the DC power cables are in the SPARC Enterprise T5120 and T5220 Servers Installation Guide To provide redundancy plug both power supplies into separate power sources Note that the system can operate with only one power connection but ...

Страница 5: ... information and your entries You will be prompted to confirm the configuration several times enabling confirmation and changes If you are not sure how to respond to a particular value you can accept the default and make future changes when the Solaris OS is running When the configuration menus are completed the server reboots and displays the Solaris login prompt 10 Log in to the server and explo...

Страница 6: ...ervers coolthreads tnb t2 jsp Technical Support If you have technical questions about this product that are not answered in this document go to http www sun com service contacting Documentation Feedback Submit comments about this document by clicking the Feedback link at http docs sun com Please include the title and part number of your document with your feedback Sun SPARC Server Enterprise T5120...

Отзывы: