The Sun Storage 2500-M2 Arrays Site Preparation Guide describes facilities and system requirements for in-

stalling Sun Storage 2500-M2 Arrays. Follow the guidelines as outlined in this document when planning your

installation.

This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by

intellectual property laws. Except as expressly permitted in your license agreement or allowed by law, you may not use, copy, reproduce, translate,

broadcast, modify, license, transmit, distribute, exhibit, perform, publish, or display any part, in any form, or by any means. Reverse engineering,

disassembly, or decompilation of this software, unless required by law for interoperability, is prohibited.
The information contained herein is subject to change without notice and is not warranted to be error-free. If you find any errors, please report them to us

in writing.
If this is software or related software documentation that is delivered to the U.S. Government or anyone licensing it on behalf of the U.S. Government, the

following notice is applicable:
U.S. GOVERNMENT RIGHTS. Programs, software, databases, and related documentation and technical data delivered to U.S. Government customers

are "commercial computer software" or "commercial technical data" pursuant to the applicable Federal Acquisition Regulation and agency-specific

supplemental regulations. As such, the use, duplication, disclosure, modification, and adaptation shall be subject to the restrictions and license terms set

forth in the applicable Government contract, and, to the extent applicable by the terms of the Government contract, the additional rights set forth in FAR

52.227-19, Commercial Computer Software License (December 2007). Oracle America, Inc., 500 Oracle Parkway, Redwood City, CA 94065.
This software or hardware is developed for general use in a variety of information management applications. It is not developed or intended for use in any

inherently dangerous applications, including applications which may create a risk of personal injury. If you use this software or hardware in dangerous

applications, then you shall be responsible to take all appropriate fail-safe, backup, redundancy, and other measures to ensure its safe use. Oracle

Corporation and its affiliates disclaim any liability for any damages caused by use of this software or hardware in dangerous applications.
Oracle and Java are registered trademarks of Oracle and/or its affiliates. Other names may be trademarks of their respective owners.
AMD, Opteron, the AMD logo, and the AMD Opteron logo are trademarks or registered trademarks of Advanced Micro Devices. Intel and Intel Xeon are

trademarks or registered trademarks of Intel Corporation. All SPARC trademarks are used under license and are trademarks or registered trademarks of

SPARC International, Inc. UNIX is a registered trademark licensed through X/Open Company, Ltd.
This software or hardware and documentation may provide access to or information on content, products, and services from third parties. Oracle

Corporation and its affiliates are not responsible for and expressly disclaim all warranties of any kind with respect to third-party content, products, and

services. Oracle Corporation and its affiliates will not be responsible for any loss, costs, or damages incurred due to your access to or use of third-party

content, products, or services.

Copyright © 2011, Oracle et/ou ses affiliés. Tous droits réservés.
Ce logiciel et la documentation qui l’accompagne sont protégés par les lois sur la propriété intellectuelle. Ils sont concédés sous licence et soumis à des

restrictions d’utilisation et de divulgation. Sauf disposition de votre contrat de licence ou de la loi, vous ne pouvez pas copier, reproduire, traduire,

diffuser, modifier, breveter, transmettre, distribuer, exposer, exécuter, publier ou afficher le logiciel, même partiellement, sous quelque forme et par

quelque procédé que ce soit. Par ailleurs, il est interdit de procéder à toute ingénierie inverse du logiciel, de le désassembler ou de le décompiler, excepté à

des fins d’interopérabilité avec des logiciels tiers ou tel que prescrit par la loi.
Les informations fournies dans ce document sont susceptibles de modification sans préavis. Par ailleurs, Oracle Corporation ne garantit pas qu’elles

soient exemptes d’erreurs et vous invite, le cas échéant, à lui en faire part par écrit.
Si ce logiciel, ou la documentation qui l’accompagne, est concédé sous licence au Gouvernement des Etats-Unis, ou à toute entité qui délivre la licence de

ce logiciel ou l’utilise pour le compte du Gouvernement des Etats-Unis, la notice suivante s’applique :
U.S. GOVERNMENT RIGHTS. Programs, software, databases, and related documentation and technical data delivered to U.S. Government customers

are "commercial computer software" or "commercial technical data" pursuant to the applicable Federal Acquisition Regulation and agency-specific

supplemental regulations. As such, the use, duplication, disclosure, modification, and adaptation shall be subject to the restrictions and license terms set

forth in the applicable Government contract, and, to the extent applicable by the terms of the Government contract, the additional rights set forth in FAR

52.227-19, Commercial Computer Software License (December 2007). Oracle America, Inc., 500 Oracle Parkway, Redwood City, CA 94065.
Ce logiciel ou matériel a été développé pour un usage général dans le cadre d’applications de gestion des informations. Ce logiciel ou matériel n’est pas

conçu ni n’est destiné à être utilisé dans des applications à risque, notamment dans des applications pouvant causer des dommages corporels. Si vous

utilisez ce logiciel ou matériel dans le cadre d’applications dangereuses, il est de votre responsabilité de prendre toutes les mesures de secours, de

sauvegarde, de redondance et autres mesures nécessaires à son utilisation dans des conditions optimales de sécurité. Oracle Corporation et ses affiliés

déclinent toute responsabilité quant aux dommages causés par l’utilisation de ce logiciel ou matériel pour ce type d’applications.
Oracle et Java sont des marques déposées d’Oracle Corporation et/ou de ses affiliés.Tout autre nom mentionné peut correspondre à des marques

appartenant à d’autres propriétaires qu’Oracle.
AMD, Opteron, le logo AMD et le logo AMD Opteron sont des marques ou des marques déposées d’Advanced Micro Devices. Intel et Intel Xeon sont des

marques ou des marques déposées d’Intel Corporation. Toutes les marques SPARC sont utilisées sous licence et sont des marques ou des marques

déposées de SPARC International, Inc. UNIX est une marque déposée concédée sous licence par X/Open Company, Ltd.
Ce logiciel ou matériel et la documentation qui l’accompagne peuvent fournir des informations ou des liens donnant accès à des contenus, des produits et

des services émanant de tiers. Oracle Corporation et ses affiliés déclinent toute responsabilité ou garantie expresse quant aux contenus, produits ou

services émanant de tiers. En aucun cas, Oracle Corporation et ses affiliés ne sauraient être tenus pour responsables des pertes subies, des coûts

occasionnés ou des dommages causés par l’accès à des contenus, produits ou services tiers, ou à leur utilisation.

Содержание Sun Storage 2500-M2 Arrays

Страница 1: ...Sun Storage 2500 M2 Arrays Site Preparation Guide Part No E20737 02 August 2011 ...

Страница 2: ...iel et la documentation qui l accompagne sont protégés par les lois sur la propriété intellectuelle Ils sont concédés sous licence et soumis à des restrictions d utilisation et de divulgation Sauf disposition de votre contrat de licence ou de la loi vous ne pouvez pas copier reproduire traduire diffuser modifier breveter transmettre distribuer exposer exécuter publier ou afficher le logiciel même ...

Страница 3: ... Secure Installation Requirements 2 Placement of a Product 2 2 Sun Storage 2500 M2 Arrays Specifications 5 Dimension and Weight Specifications 6 Environmental Requirements 7 Humidity 7 Altitude 8 Airflow and Heat Dissipation 8 Acoustic Noise 9 Shock and Vibration 9 Electrical Requirements 9 Site Wiring and Power 10 AC Power Input 11 ...

Страница 4: ...eparation Guide August 2011 DC Power Input 11 Controller Tray Power Factor Correction 11 Power Cords and Receptacles 11 AC Power Cords 11 DC Power Connector Cables 12 Battery Life 12 A Configuration Worksheets 13 ...

Страница 5: ... helps you make decisions about ventilation electrical power floor loading and network configuration Conduct a power survey to make sure that the storage array and input power is free of noise spikes and fluctuations Before You Read This Guide Before you begin to install Sun Storage 2500 M2 Arrays you must have already read the regulatory and safety requirements described in this book Sun Storage ...

Страница 6: ...s Sun Storage Common Array Manager Release Notes Prepare the site Sun Storage 2500 M2 Arrays Site Preparation Guide Install the array Sun Storage 2500 M2 Arrays Hardware Installation Guide Install the management software Sun Storage Common Array Manager Quick Start Guide Sun Storage Common Array Manager Installation and Setup Guide Install multipath driver Sun StorageTek MPIO Device Specific Modul...

Страница 7: ...s concerning facilities The customer is also required to do the following Comply with all local national and international codes covered in this specification The subjects covered include fire and safety building and electrical codes Document and inform Oracle Corporation of any deviations from this specification Safety Information Install Sun Storage 2500 M2 Arrays in accordance with the local sa...

Страница 8: ...or Move the cabinet slowly and deliberately and make sure that the floor is free from foreign objects and cables that the cabinet could roll over Caution To avoid injury wear protective footwear when moving a system Secure Installation Requirements To minimize personnel injury in the event of a seismic occurrence you must securely fasten the cabinet to a rigid structure extending from the floor to...

Страница 9: ...ter Failure to follow these guidelines can cause overheating and affect the reliability of your product Air cools the system cabinets from front to back Air enters at the front circulates and is expelled at the back of the cabinet The front and back door clearances provide sufficient space for cooling See Chapter 2 for specific clearance specifications ...

Страница 10: ...4 Site Preparation Guide August 2011 ...

Страница 11: ... chapter describes the physical environmental and electrical requirements for the Sun Storage 2500 M2 Arrays It contains the following sections Dimension and Weight Specifications on page 6 Environmental Requirements on page 7 Electrical Requirements on page 9 ...

Страница 12: ...ents installed Because drive weights can vary this value can vary from the value specified as much as either 0 66 lb 0 3 kg times the maximum number of drives per controller tray for 3 5 in SATA drives or 0 18 lb 0 08 kg times the maximum number of drives per controller tray for 2 5 in SATA drives Weight Empty Empty weight indicates a controller tray with the controller modules the power fan modul...

Страница 13: ...eet to 9842 feet 1000 meters to 3000 meters above sea level lower the environmental temperature 3 3 F 1 7 C for every 3280 feet 1000 meters above sea level Parameter Requirement Operating range both cabinet and subsystem 50 F to 104 F 10 C to 40 C Maximum rate of change 50 F 10 C per hour Storage range 14 F to 122 F 10 C to 50 C Maximum rate of change 59 F 15 C per hour Transit change 40 F to 140 ...

Страница 14: ... ft 30 5 m below sea level to 9840 ft 3000 m above sea level Storage 100 ft 30 5 m below sea level to 9840 ft 3000 m above sea level Transit 100 ft 30 5 m below sea level to 40 000 ft 12 000 m above sea level TABLE 2 7 Airflow and Minimum Clearance Position Clearance Front 30 in 76 cm Back 24 in 61 cm TABLE 2 8 Power and Heat Dissipation for the Controller Tray Component KVA Watts AC Btu Hr Contro...

Страница 15: ...ies meet standard voltage requirements for both North American USA and Canada operation and worldwide except USA and Canada operation They use standard industrial wiring with line to neutral or line to line power connections TABLE 2 9 Acoustic Noise at 25 C for the Controller Tray Measurement Level Sound power standby operation 6 2 bels maximum Sound pressure normal operation 6 2 bels maximum TABL...

Страница 16: ...its and associated circuit breakers must provide sufficient power and overload protection To prevent possible damage to the array isolate its power source from large switching loads such as air conditioning motors elevator motors and factory loads Power interruptions The controller tray can withstand the following applied voltage interruptions with or without an integrated uninterruptible power su...

Страница 17: ...rection Power factor correction is applied within the power supply which maintains the power factor of the controller tray at greater than 0 95 with nominal input voltage Power Cords and Receptacles Sun Storage 2500 M2 Arrays are shipped with either two AC power cords or two DC power cords per tray depending on the configuration ordered AC Power Cords Each AC power cord connects one of the power s...

Страница 18: ...connected by removing all power connectors from the power supplies Two optionally four DC power connector cables are provided with each controller or expansion tray Two DC power connectors are on the back of each tray s DC power supply if additional redundancy is required Note It is not mandatory that the second DC power connection on the array s DC power supplies be connected The second DC power ...

Страница 19: ...he information you need to collect to configure the array TABLE A 1 Sun Storage 2500 M2 Arrays Configuration Worksheet Controller A MAC address Controller B MAC address Controller A IP address Controller B IP address Management host IP address Network mask Name server domain name IP address of the domain name server DNS Gateway IP address Email notification address ...

Страница 20: ...rmation you need to collect for each data host connected to Sun Storage 2500 M2 Arrays TABLE A 2 Sun Storage 2500 M2 Arrays Data Host Information Host name Vendor Model Operating system Patch Service pack Number of HBAs HBA World Wide Name WWN HBA model HBA driver ...