150
SPARC T3-2 Server Service Manual • December 2013
▼
Remove a PCIe Card
Caution –
This procedure requires that you handle components that are sensitive to
static discharge. This sensitivity can cause the component to fail. To avoid damage,
ensure that you follow antistatic practices as described in
“ESD Measures” on
page 63
.
This procedure can be performed by customers. The system must be completely
powered down before performing this procedure. See
“Cold Service, Replaceable by
Customer” on page 67
for more information about cold service procedures.
1. Prepare for servicing:
a. Attach an antistatic wrist strap.
b. Power off the server and disconnect all power cords from the server power
supplies.
See
“Removing Power From the System” on page 69
.
c. Extend the server to the maintenance position.
See
“Extend the Server to the Maintenance Position” on page 72
.
d. Remove the top cover.
See
“Remove the Server Top Cover” on page 76
2. Locate the PCIe card that you want to remove.
See
“Rear Components” on page 3
for information about PCIe slots and their
locations.
3. If necessary, make a note of where the PCIe cards are installed.
4. Unplug all data cables from the PCIe card.
Note the location of all cables for reinstallation later.
5. Remove the PCIe card filler panel by completing the following tasks.
Содержание SPARC T3-2
Страница 1: ...SPARC T3 2 Server Service Manual Part No E20793 05 December 2013 ...
Страница 10: ...x SPARC T3 2 Server Service Manual December 2013 ...
Страница 26: ...14 SPARC T3 2 Server Service Manual December 2013 ...
Страница 72: ...60 SPARC T3 2 Server Service Manual December 2013 ...
Страница 112: ...100 SPARC T3 2 Server Service Manual December 2013 ...
Страница 120: ...108 SPARC T3 2 Server Service Manual December 2013 ...
Страница 150: ...138 SPARC T3 2 Server Service Manual December 2013 ...
Страница 157: ...Servicing the System Lithium Battery 145 Related Information Install the System Battery on page 146 ...
Страница 174: ...162 SPARC T3 2 Server Service Manual December 2013 ...
Страница 186: ...174 SPARC T3 2 Server Service Manual December 2013 ...
Страница 194: ...182 SPARC T3 2 Server Service Manual December 2013 ...
Страница 200: ...188 SPARC T3 2 Server Service Manual December 2013 ...
Страница 206: ...194 SPARC T3 2 Server Service Manual December 2013 ...
Страница 212: ...200 SPARC T3 2 Server Service Manual December 2013 ...
Страница 216: ...204 SPARC T3 2 Server Service Manual December 2013 ...
Страница 222: ...210 SPARC T3 2 Server Service Manual December 2013 ...