Sun Oracle SPARC T3-1 Скачать руководство пользователя страница 4

4

FIGURE 2

Server Connections

4. (Optional) Connect an Ethernet cable between the server’s NET MGT port (

FIGURE 2

) and the network to

which future connections to the SP and host will be made.

After the initial configuration of the system using the SER MGT port, communication with the SP and host is
usually performed through this Ethernet interface.

5. Connect an Ethernet cable between one of the server’s NET ports (

FIGURE 2

) and the network to which the

server will communicate.

6. Plug the power cords into the power supplies and into separate power sources.

If your server is equipped with two power supplies, plug them into separate power sources. This will
provide your system with power redundancy. The system can operate with one power connection, but this
removes the redundancy.

When power is applied, the SP initializes and power supply LEDs illuminate. After a few minutes, the SP
login prompt appears on the terminal device. Note that the host is not initialized or powered on yet.

Содержание SPARC T3-1

Страница 1: ...uctions for your situation The quick setup instructions in this guide work for any networking environment and require the use of a terminal device for connection to a serial port If you have a networking environment running DHCP you can configure your system using the Ethernet management port To take advantage of the DHCP setup method refer to the online installation guide in the online product do...

Страница 2: ... device Network Select Yes Multiple Network Interfaces Select the network interfaces that you plan to configure If you are not sure select the first one in the list DHCP Select Yes or No according to your network environment Host Name Enter the host name for the server IP Address Enter the IP address for the selected Ethernet interfaces Subnet Select Yes or No according to your network environment...

Страница 3: ...This connection provides your initial communication with the SP The device must be set up to communicate using 9600 baud 8 bit no parity 1 stop bit A null modem configuration is needed meaning the transmit and receive signals are reversed crossed over for DTE to DTE communications You can use the supplied RJ 45 crossover adapter with a standard RJ 45 cable to achieve the null modem configuration T...

Страница 4: ... the server s NET ports FIGURE 2 and the network to which the server will communicate 6 Plug the power cords into the power supplies and into separate power sources If your server is equipped with two power supplies plug them into separate power sources This will provide your system with power redundancy The system can operate with one power connection but this removes the redundancy When power is...

Страница 5: ...mation and your entries You will be prompted to confirm the configuration several times enabling confirmation and changes If you are not sure how to respond to a particular value you can accept the default and make future changes when the Oracle Solaris OS is running When the configuration menus are completed the server reboots and displays the Oracle Solaris login prompt 10 Log in to the server a...

Страница 6: ...his document go to http www sun com service contacting Documentation Feedback Submit comments about this document by clicking the Feedback link at http docs sun com Please include the title and part number of your document with your feedback SPARC T3 1 Server Getting Started Guide part number 821 2060 10 Copyright 2010 Oracle and or its affiliates All rights reserved Copyright 2010 Oracle et ou se...

Отзывы: