26
SPARC T3-1B Server Module Service Manual • July 2012
■
“Managing Faults (Oracle ILOM)” on page 12
■
“Interpreting Log Files and System Messages” on page 23
■
“Managing Faults (POST)” on page 31
■
“Managing Components (ASR Commands)” on page 44
■
“Checking if Oracle VTS Software Is Installed” on page 48
■
Oracle Solaris PSH Technology Overview
The Oracle Solaris PSH technology enables the server module to diagnose problems
while the Oracle Solaris OS is running and to mitigate many problems before they
negatively affect operations.
The Oracle Solaris OS uses the fault manager daemon,
fmd
(1M), which starts at boot
time and runs in the background to monitor the system. If a component generates an
error, the daemon correlates the error with data from previous errors and other
relevant information to diagnose the problem. Once diagnosed, the fault manager
daemon assigns a UUID to the error. This value distinguishes this error across any set
of systems.
When possible, the fault manager daemon initiates steps to self-heal the failed
component and take the component offline. The daemon also logs the fault to the
syslogd
daemon and provides a fault notification with a message ID (sometimes
labeled MSG-ID). You can use the message ID to get additional information about the
problem from the knowledge article database.
The PSH technology covers the following server module components:
■
CPU
■
Memory
■
I/O subsystem
The PSH console message provides the following information about each detected
fault:
■
Type
■
Severity
■
Description
■
Automated response
■
Impact
■
Suggested action for system administrator
Содержание Netra SPARC T3-1B
Страница 1: ...SPARC T3 1B Server Module Service Manual Part No E29280 02 July 2012 ...
Страница 7: ...Contents vii Start the Server Module Host 114 Glossary 115 Index 121 ...
Страница 8: ...viii SPARC T3 1B Server Module Service Manual July 2012 ...
Страница 12: ...xii SPARC T3 1B Server Module Service Manual July 2012 ...
Страница 100: ...88 SPARC T3 1B Server Module Service Manual July 2012 Related Information Remove a REM on page 85 ...
Страница 116: ...104 SPARC T3 1B Server Module Service Manual July 2012 ...
Страница 131: ...Glossary 119 W WWID World wide identifier A unique number that identifies a SAS target ...
Страница 132: ...120 SPARC T3 1B Server Module Service Manual July 2012 ...