Sun Microsystems Ultra 2 UltraSPARC-II Скачать руководство пользователя страница 3

Please

Recycle

Copyright 1999 Sun Microsystems, Inc., 901 San Antonio Road, Palo Alto, California 94303-4900 U.S.A. All rights reserved.

This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation.
No part of this product or document may be reproduced in any form by any means without prior written authorization of Sun and its licensors,
if any.

Portions of this product may be derived from the UNIX® system, licensed from Novell, Inc., and from the Berkeley 4.3 BSD system, licensed
from the University of California. UNIX is a registered trademark in the United States and in other countries and is exclusively licensed by
X/Open Company Ltd. Third-party software, including font technology in this product, is protected by copyright and licensed from Sun’s
suppliers. RESTRICTED RIGHTS: Use, duplication, or disclosure by the U.S. Government is subject to restrictions of FAR 52.227-14(g)(2)(6/87)
and FAR 52.227-19(6/87), or DFAR 252.227-7015(b)(6/95) and DFAR 227.7202-3(a).

Sun, Sun Microsystems, the Sun logo, AnswerBook, SunDocs, Ultra, OpenBoot, UltraSPARC, and Solaris are trademarks or registered
trademarks of Sun Microsystems, Inc. in the United States and in other countries. All SPARC trademarks are used under license and are
trademarks or registered trademarks of SPARC International, Inc. in the United States and in other countries. Products bearing SPARC
trademarks are based upon an architecture developed by Sun Microsystems, Inc.

The OPEN LOOK® and Sun™ Graphical User Interfaces were developed by Sun Microsystems, Inc. for its users and licensees. Sun
acknowledges the pioneering efforts of Xerox Corporation in researching and developing the concept of visual or graphical user interfaces for
the computer industry. Sun holds a nonexclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun’s
licensees who implement OPEN LOOK GUIs and otherwise comply with Sun’s written license agreements.

THIS PUBLICATION IS PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-
INFRINGEMENT.

Copyright 1999 Sun Microsystems, Inc., 901 San Antonio Road, Palo Alto, Californie 94303-4900 U.S.A. Tous droits réservés.

Ce produit ou document est protégé par un copyright et distribué avec des licences qui en restreignent l’utilisation, la copie et la décompilation.
Aucune partie de ce produit ou de sa documentation associée ne peut être reproduite sous aucune forme, par quelque moyen que ce soit, sans
l’autorisation préalable et écrite de Sun et de ses bailleurs de licence, s’il y en a.

Des parties de ce produit pourront être derivées du système UNIX® licencié par Novell, Inc. et du système Berkeley 4.3 BSD licencié par
l’Université de Californie. UNIX est une marque enregistrée aux Etats-Unis et dans d’autres pays, et licenciée exclusivement par X/Open
Company Ltd. Le logiciel détenu par des tiers, et qui comprend la technologie relative aux polices de caractères, est protégé par un copyright et
licencié par des fournisseurs de Sun.

Sun, Sun Microsystems, le logo Sun, AnswerBook, SunDocs, Ultra, OpenBoot, UltraSPARC, et Solaris sont des marques déposées ou
enregistrées de Sun Microsystems, Inc. aux Etats-Unis et dans d’autres pays. Toutes les marques SPARC, utilisées sous licence, sont des marques
déposées ou enregistrées de SPARC International, Inc. aux Etats-Unis et dans d’autres pays. Les produits portant les marques SPARC sont basés
sur une architecture développée par Sun Microsystems, Inc.

Les utilisateurs d’interfaces graphiques OPEN LOOK® et Sun™ ont été développés de Sun Microsystems, Inc. pour ses utilisateurs et licenciés.
Sun reconnaît les efforts de pionniers de Xerox Corporation pour la recherche et le développement du concept des interfaces d’utilisation
visuelle ou graphique pour l’industrie de l’informatique. Sun détient une licence non exclusive de Xerox sur l’interface d’utilisation graphique,
cette licence couvrant aussi les licenciés de Sun qui mettent en place les utilisateurs d’interfaces graphiques OPEN LOOK et qui en outre se
conforment aux licences écrites de Sun.

CETTE PUBLICATION EST FOURNIE "EN L’ETAT" SANS GARANTIE D’AUCUNE SORTE, NI EXPRESSE NI IMPLICITE, Y COMPRIS, ET

SANS QUE CETTE LISTE NE SOIT  LIMITATIVE, DES GARANTIES CONCERNANT LA VALEUR MARCHANDE, L’APTITUDE  DES

PRODUITS A REPONDRE A UNE UTILISATION PARTICULIERE OU LE FAIT QU’ILS NE SOIENT PAS CONTREFAISANTS DE PRODUITS

DE TIERS.

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание Ultra 2 UltraSPARC-II

Страница 1: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Страница 2: ...er 1999 Revision A Sun Microsystems Inc 901 San Antonio Road Palo Alto CA 94303 4900 USA 650 960 1300 Fax 650 969 9131 Send comments about this document to docfeedback sun com Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 3: ...pyright 1999 Sun Microsystems Inc 901 San Antonio Road Palo Alto Californie 94303 4900 U S A Tous droits réservés Ce produit ou document est protégé par un copyright et distribué avec des licences qui en restreignent l utilisation la copie et la décompilation Aucune partie de ce produit ou de sa documentation associée ne peut être reproduite sous aucune forme par quelque moyen que ce soit sans l a...

Страница 4: ...e Kit 1 3 2 Opening the System Unit 2 1 2 1 Removing Power from the System 2 1 2 2 Removing the System Unit Cover 2 3 2 3 Attaching the Wrist Strap 2 5 3 Installing the UltraSPARC II Module 3 1 3 1 Updating the Flash PROM 3 1 3 2 Removing the UltraSPARC Module 3 1 3 3 Installing the UltraSPARC II Module 3 3 3 4 Completing the Installation 3 7 3 4 1 Changing the Clocking Select Jumper 3 7 Artisan T...

Страница 5: ...9 3 4 2 Closing the System Unit 3 9 3 4 3 Turning On the Power 3 11 3 4 4 Power On Self Test POST 3 11 3 4 5 EnergyStar 3 11 3 4 6 Returning the Removed Module s 3 12 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 6: ...uency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try t...

Страница 7: ...otice Canada This digital apparatus does not exceed the Class B limits for radio noise emission for a digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications Avis concernant les systèmes appartenant à la classe B du DOC Canada Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils n...

Страница 8: ... vii Nippon Japan Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 9: ... viii Sun Ultra 2 UltraSPARC II Module Upgrade October 1999 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 10: ...ing an UltraSPARC II module upgrade in a Sun Ultra 2 system The Sun Ultra 2 system can now support a 400 Mhz CPU if the motherboard is part number 501 3132 13 or higher FIGURE 1 1 Ultra 2 System Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 11: ...odule s already installed in your system Query your system by typing The system responds with the quantity for example 2 x and speed 168 MHz of the UltraSPARC module s installed TABLE 1 1 Minimum Solaris Operating Environment CPU Frequency Solaris Release 167 MHz 2 5 1 200 MHz 2 5 1 Hardware 4 97 250 MHz 2 5 1 Hardware 8 97 300 MHz 2 5 1 Hardware 11 97 2 6 Hardware 3 98 400 MHz 2 5 1 Hardware 11 9...

Страница 12: ...software that conform to SCD version 2 1 FIGURE 1 2 SCD Compliance 1 4 UltraSPARC II Module Upgrade Kit Each UltraSPARC II module upgrade kit contains This book UltraSPARC II module UPA terminator module for 300 MHz uniprocessor systems only Antistatic wrist strap Flash PROM update CD ROM and programming guide Note Retain the packing box and shipping material for use in returning the removed modul...

Страница 13: ...1 4 Sun Ultra 2 UltraSPARC II Module Upgrade October 1999 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 14: ... Refer to the Solaris Handbook for the procedure 2 Back up the system files and data Refer to the Solaris Handbook for the procedure 3 Shut down the system 4 Turn the power off to the monitor and all peripherals connected to the system 5 Remove DC power from the system by pressing the Standby side of the power switch on the back panel FIGURE 2 1 Note After the Standby switch is pressed it returns ...

Страница 15: ...r safely discharging static electricity Note where each cord and cable attaches to the system unit Caution When the Power On Standby switch is pressed and the AC power cord remains connected to a power outlet hazardous AC voltage is still present in the power supply primary FIGURE 2 1 Standby Switch Standby Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 16: ...move the lock block if installed on the top cover and back panel FIGURE 2 3 2 Pull the two top cover plastic tabs towards yourself 3 Lift the top cover so that it clears the chassis and push the cover forward so that it clears the chassis FIGURE 2 4 LED Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 17: ...C II Module Upgrade October 1999 FIGURE 2 3 Opening the System Unit FIGURE 2 4 Lifting the Top Cover Plastic tab Plastic tab Lock block Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 18: ... Attaching the Wrist Strap FIGURE 2 6 Power Supply Location Attach end to metal casing of power supply Wrap the wrist strap twice around your wrist adhesive against your skin Power supply Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 19: ...2 6 Sun Ultra 2 UltraSPARC II Module Upgrade October 1999 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 20: ...he motherboard is part number 501 3132 13 or higher Note The motherboard part number is located on the right front side of the motherboard See FIGURE 3 6 on page 8 to locate the motherboard part number stamp Skip this section and read Section 3 3 Installing the UltraSPARC II Module on page 3 3 if your system is already equipped with one UltraSPARC II module and you are adding a second module of th...

Страница 21: ...processor area see FIGURE 3 1 2 With the thumbs of both hands simultaneously lift the two levers on the module upwards and to the side about 135 degrees FIGURE 3 2 3 Lift the module upwards until it clears the system chassis 4 Place the module on an antistatic surface Slot 0 Slot 1 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 22: ...e Caution All CPUs must have the same clock speed 1 Unpack the UltraSPARC II processor module 2 Place the module on an antistatic surface 3 Identify the appropriate or available slot FIGURE 3 3 90 degrees 135 degrees 90 degrees 135 degrees Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 23: ...nt side of the motherboard See FIGURE 3 6 on page 8 to locate the motherboard part number stamp If your system is equipped with two UltraSPARC II modules slot 0 and slot 1 will each have a module installed TABLE 3 1 UPA Terminator Module Necessity Motherboard Part Number 167 MHz CPU 200 MHz CPU 250 MHz CPU 300 MHz CPU 400 MHz CPU 501 3132 01 through 08 No No No NS Not supported NS 501 3132 09 thro...

Страница 24: ...uides until the module touches the slot socket on the main logic board FIGURE 3 4 Lowering the Module Into the Chassis 7 With both hands simultaneously turn and press the levers downward to the fully horizontal position Firmly press the module downward into the socket until it is fully seated and the levers are fully locked FIGURE 3 5 90 degrees 135 degrees 90 degrees 135 degrees Artisan Technolog...

Страница 25: ...8 If your system has only one UltraSPARC II module installed in slot 0 follow Steps 5 through 7 of this procedure to install the UPA terminator 501 4843 01 in slot 1 if necessary Refer to TABLE 3 1 on page 4 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 26: ... board and the two available jumper settings respectively To change the jumper use needlenose pliers to remove the jumper from position A and to install the jumper at position B see FIGURE 3 7 TABLE 3 2 UltraSPARC Module Clocking Select Jumper Settings Jumper Pins 1 2 Select Pins 2 3 Select J2301 250 MHz or 300 MHz UltraSPARC II modules All UltraSPARC I 168 MHz or 200 MHz or 400 MHz UltraSPARC II ...

Страница 27: ...ect Jumper Location on Ultra 2 Motherboard Back Panel Motherboard Fan Fan Power Supply J2801 J2901 CPU 0 CPU 1 J3002 Fan Fan Speaker Front Panel Right Panel J2301 Left Panel Part number label Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 28: ...it Seat the cover lip to the chassis lip 3 Slowly lower the cover onto the system unit so that the rear of the cover seats with the chassis back panel see FIGURE 3 8 J2301 J2301 J2301 Pin 1 Pin 2 Pin 3 Default jumper position UltraSPARC I modules 168 MHz and 200 MHz Jumper position UltraSPARC II modules 250 MHz and 300 MHz A B UltraSPARC II 400 MHz Artisan Technology Group Quality Instrumentation ...

Страница 29: ...stic tabs in place onto the back panel You will hear a click as each tab seats with the back panel see FIGURE 3 9 5 Use a Phillips screwdriver to reinstall the lock block to the back panel FIGURE 3 9 Cover Tabs and Lock Block Plastic tab Plastic tab Lock block Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 30: ...n the system unit back panel 3 The operating system should load or the ok prompt should appear on the monitor FIGURE 3 10 Power On Standby Switch 3 4 4 Power On Self Test POST For a full description of the Power On Self Test POST refer to the Sun Ultra 2 Service Manual 3 4 5 EnergyStar If you experience RED State Exception failures when exercising EnergyStar suspend resume functions on Solaris 2 5...

Страница 31: ...module s and 1 Place the removed module s in the antistatic bag s 2 Fold and tape the end s of the bag s 3 Place the bag s and other shipping materials in the shipping box 4 Affix the RMA Return Material Authorization label from the upgrade kit onto the shipping carton 5 Return the shipping carton to Sun Microsystems Inc Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www...

Страница 32: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Отзывы: