background image

x

Sun Netra X4200 M2 Server Safety and Compliance Guide • May 2009

manager or a qualified electrician if you are
not sure what type of power is supplied to
your building.

Caution –

Not all power cords have the same

current ratings. Do not use the power cord
provided with your equipment for any other
products or use. Household extension cords
do not have overload protection and are not
meant for use with computer systems. Do not
use household extension cords with your Sun
product.

The following caution applies only to devices with a
Standby power switch:

Caution –

The power switch of this product

functions as a standby type device only. The
power cord serves as the primary disconnect
device for the system. Be sure to plug the
power cord into a grounded power outlet that
is nearby the system and is readily accessible.
Do not connect the power cord when the
power supply has been removed from the
system chassis.

The following caution applies only to devices with multiple
power cords:

Caution –

For products with multiple power

cords, all power cords must be disconnected
to completely remove power from the system.

Battery Warning

Caution –

There is danger of explosion if

batteries are mishandled or incorrectly
replaced. On systems with replaceable
batteries, replace only with the same
manufacturer and type or equivalent type
recommended by the manufacturer per the
instructions provided in the product service
manual. Do not disassemble batteries or
attempt to recharge them outside the system.
Do not dispose of batteries in fire. Dispose of
batteries properly in accordance with the
manufacturer’s instructions and local
regulations. Note that on Sun CPU boards,
there is a lithium battery molded into the real-
time clock. These batteries are not customer
replaceable parts.

System Unit Cover

You must remove the cover of your Sun computer system
unit to add cards, memory, or internal storage devices. Be
sure to replace the cover before powering on your computer
system.

Caution –

Do not operate Sun products

without the cover in place. Failure to take this
precaution may result in personal injury and
system damage.

Rack System Instructions

The following or similar rack-mount instructions are
included with the installation instructions:

Elevated Operating Ambient

– If installed in a closed

or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater
than room ambient. Therefore, consideration should
be given to installing the equipment in an
environment compatible with the maximum ambient
temperature (Tma) specified by the manufacturer.

Reduced Air Flow

– Installation of the equipment in a

rack should be such that the amount of air flow
required for safe operation of the equipment is not
compromised.

Mechanical Loading

– Mounting of the equipment in

the rack should be such that a hazardous condition is
not achieved due to uneven mechanical loading.

Содержание Sun Fire X4200 M2

Страница 1: ...omments about this document by clicking the Feedback link at http docs sun com Sun NetraTM X4200 M2 Server Safety and Compliance Guide Part No 820 0068 11 May 2009 Revision A Sun Microsystems Inc www...

Страница 2: ...HE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Copyright 2009 Sun Microsystems Inc 4150 Network Circle Santa Clara Californie 95054 tats Unis Tous droits r serv s Sun Microsystems Inc...

Страница 3: ...iii Contents Declaration of Conformity AC v Declaration of Conformity DC vi Regulatory Compliance Statements vii Safety Agency Compliance Statements ix Shielded Cables xxi...

Страница 4: ...iv Sun Netra X4200 M2 Server Safety and Compliance Guide May 2009...

Страница 5: ...1400 2000 MHz IEC61000 4 4 1 kV AC and DC Power Lines 0 5 kV Signal Lines IEC61000 4 5 2 kV AC Line Gnd 1 kV AC Line Line and Outdoor Signal Lines 0 5 kV Indoor signal Lines 10m IEC61000 4 6 3 V IEC6...

Страница 6: ...0 1000MHz 10 V m 800 960 MHz and 1400 2000 MHz IEC61000 4 4 1 kV AC and DC Power Lines 0 5 kV Signal Lines IEC61000 4 5 2 kV AC Line Gnd 1 kV AC Line Line and Outdoor Signal Lines 0 5 kV Indoor signal...

Страница 7: ...the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can...

Страница 8: ...Safety and Compliance Guide May 2009 CCC Class A Notice The following statement is applicable to products shipped to China and marked with Class A on the product s compliance label GOST R Certificati...

Страница 9: ...d contact Surfaces are hot and may cause personal injury if touched Caution Hazardous voltages are present To reduce the risk of electric shock and danger to personal health follow the instructions De...

Страница 10: ...manufacturer per the instructions provided in the product service manual Do not disassemble batteries or attempt to recharge them outside the system Do not dispose of batteries in fire Dispose of batt...

Страница 11: ...rez vous que la tension et la fr quence de votre source d alimentation correspondent la tension et la fr quence indiqu es sur l tiquette de la tension lectrique nominale du mat riel N introduisez jama...

Страница 12: ...ristiques lectriques Les cordons d alimentation usage domestique ne sont pas prot g s contre les surtensions et ne sont pas con us pour tre utilis s avec des ordinateurs N utilisez jamais de cordon d...

Страница 13: ...circuits sur la protection de surintensit et sur le c blage d alimentation En l occurrence les valeurs nominales de la plaque signal tique du mat riel doivent tre prises en compte Mise la terre fiabl...

Страница 14: ...odukten nicht haftbar Aufstellung von Sun Ger ten Achtung Ger te ffnungen Ihres Sun Produkts d rfen nicht blockiert oder abgedeckt werden Sun Ger te sollten niemals in der N he von Heizk rpern oder He...

Страница 15: ...Speicherger te hinzuzuf gen Bringen Sie vor dem Einschalten des Systems die Geh useabdeckung wieder an Achtung Nehmen Sie Sun Ger te nicht ohne Abdeckung in Betrieb Die Nichtbeachtung dieses Warnhinw...

Страница 16: ...escargas el ctricas o da os en el equipo Este producto se ha concebido para un acceso restringido y por tanto ste se controla mediante mecanismos de seguridad p ej acceso con clave bloqueo herramienta...

Страница 17: ...s inform ticos No utilice alargadores de uso dom stico con el producto Sun La siguiente medida solamente se aplica a aquellos dispositivos que dispongan de un interruptor de alimentaci n de espera Pre...

Страница 18: ...consecuencias que puede tener la sobrecarga de los circuitos en la protecci n de sobrecorriente y el cableado de alimentaci n En caso de sobrecarga es recomendable tener en cuenta la potencia del equi...

Страница 19: ...designed for an IT power distribution system with phase to phase voltage of 230V Danmark Advarsel Dette produkt er ogs beregnet til et IT str mfordelingssystem med en fase til fase sp nding p 230 V N...

Страница 20: ...xx Sun Netra X4200 M2 Server Safety and Compliance Guide May 2009...

Страница 21: ...c bles paires torsad es non blind es German Kabelverbindungen zwischen Workstations und Peripherieger ten m ssen mithilfe von abgeschirmten Kabeln hergestellt werden um den Grenzwerten f r die Hochfre...

Страница 22: ...xxii Sun Netra X4200 M2 Server Safety and Compliance Guide May 2009...

Отзывы: