Physical Dimensions

These are the physical specifications for the Sun Fire T1000 server.

Description

U.S.

Metric

Width

16.8 in.

425 mm

Depth

19.0 in.

483 mm

Height

1.75 in., 1 rack unit

43 mm

Weight (without PCI card and rackmounts)

20 lb

9.1 kg

Weight (with slide rails)

24 lbs

10.9 kg

Содержание Sun Fire T1000

Страница 1: ...Sun Microsystems Inc www sun com Submit comments about this document at http www sun com hwdocs feedback Sun Fire T1000 Server Site Planning Guide Part No 819 3749 11 July 2006 Revision A...

Страница 2: ...VALID Copyright 2006 Sun Microsystems Inc 4150 Network Circle Santa Clara Californie 95054 Etats Unis Tous droits r serv s Sun Microsystems Inc a les droits de propri t intellectuels relatants la tech...

Страница 3: ...ocument that came with your system This guide contains the following sections Physical Dimensions on page 1 Clearance for Service Access on page 2 Environmental Specifications on page 2 Power Source R...

Страница 4: ...n Clearance front of system 36 in 91 cm Clearance rear of system 36 in 91 cm Description Specification Operating Temperature Sea level to 3000 ft 900m Above 3000 ft 900m 41 F to 95 F 5 C to 35 C Decre...

Страница 5: ...escription Specification Operating input voltage range 100 to 240 VAC 50 60 Hz Input voltage tolerance 10 Maximum operating input current 2 2 A at 100 to 120 VAC 1 1 A at 200 to 240 VAC Typical operat...

Страница 6: ...viations IEC825 1 2 CFR21 part 1040 CNS14336 GB4943 RFI EMI EN55022 Class A 47 CFR 15B Class A ICES 003 Class A VCCI Class A AS NZ 3548 Class A CNS 13438 Class A KSC 5858 Class A GB9254 Class A EN6100...

Страница 7: ...tal Specifications on page 2 Operating computer equipment in extremes of temperature or humidity increases the failure rate of hardware components To minimize the chance of component failure use the s...