1-20
Sun StorEdge D2 Array Installation, Operation, and Service Manual • February 2002
1.8.1
Single-Bus Configuration
In a single-bus configuration, a single ESM controls all the disks. (
shows
how the disks are numbered.)
■
A single ESM must be in position 0, which is the left slot as viewed from the rear
of the enclosure.
■
A filler must be in position 1, which is the right slot as viewed from the rear.
■
Switch number 1 in the switch bank on the front of the ESM must be set Up.
shows a single ESM connected to a single host adapter on a single host.
Another configuration that is not illustrated, but also supported is connecting the
Sun StorEdge D2 array to an embedded SCSI connection.
FIGURE 1-13
Single-Bus Configuration With a Single ESM, One Host Adapter, and a Single
Host
Note –
The SCSI cable from a host can be connected to either the SCSI-A or SCSI-B
connector on the ESM.
Switch Bank
ESM in Position 0
Filler in Position 1
Содержание StorEdge D2
Страница 10: ...x Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Страница 50: ...2 12 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Страница 92: ...4 28 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Страница 98: ...B 2 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Страница 104: ...B 8 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Страница 114: ...B 18 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Страница 118: ...Index 4 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...