4-16
Sun StorEdge D2 Array Installation, Operation, and Service Manual • February 2002
4.5
Removing and Replacing a Power
Supply
Perform the following procedure.
▼
To Remove and Replace a Power Supply
As shown in
, the amber LED on a power supply indicates that either the
power supply has failed or that the power supply’s power cord is disconnected.
Although the system can run well with only one power supply, a faulty power
supply should be replaced in case the remaining good one fails. You can replace a
failed or failing power supply without turning the array off.
1. Disconnect the power cord from the power supply you intend to replace.
You cannot remove the power supply without first disconnecting the power cord.
See
for the locations of the power connector and locking handle.
FIGURE 4-5
Removing and Replacing a Power Supply
Locking handle