![Sun Microsystems StorEdge 3310 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/sun-microsystems/storedge-3310/storedge-3310_best-practices-manual_1392460020.webp)
16
Sun StorEdge 3000 Family Best Practices Manual
• May
2005
Application Server Tips and Techniques
Consider the following tips and techniques when configuring application servers.
■
A single RAID array providing storage for two servers reduces storage costs with
little to no effect on application performance.
■
Use the built-in SCSI ports of application servers to further minimize costs rather
than adding a host adapter, particularly when not using Gigabit Ethernet to the
LAN. Even a 40 MB/sec SCSI port is several times faster than a Fast Ethernet
port.
■
A second RAID controller can be added to enhance RAS without adding disks
and creating a second logical drive. Redundant RAID controllers will operate in
an active-standby mode when only one logical drive is available.
■
Enhance application server availability by booting them from the RAID array
rather than their internal drives. This also facilitates the rapid replacement of
malfunctioning or failed servers.
■
If attaching the RAID array to multiple hosts, assign a separate LUN to each
server and SCSI bus.
TABLE
5
Configuration Details for Application Servers
Small Configuration
Large Configuration
RAID Enclosures
1
1
JBOD Enclosures
0
0
Number of Controllers
1
2
Number of Disks
5
12
Bus Configuration
Split Bus
Split Bus
Cache Optimization
Random
Random
RAID Levels Used
RAID 5
RAID 5
Drive Configuration
One LUN
One spare drive
Two LUNs