316196601 • Revision: A
Chapter 3 Virtual Operator Panel
25
Diagnose Drive Tab
Get Log
If a Dione card or connection is consistently having problems, engineering may
request you retrieve a log of events from the Dione card.
1. Click Get Log.
2. Create and select a location for the file.
Once the file has transferred, the operation is complete.
Load Firmware
To load new Dione card firmware:
Obtain the firmware and place it in a directory file easy to locate.
Click on Load Firmware.
A dialog box opens requesting the location of the firmware.
Navigate to that location and load the files.
Note there are two files to download: *.bin and *.hdr.
FIGURE 3-9
Run LED Diag