3. Display Cabinet 

 
 
 
 

 
 

 

Actual measured brake force  

Information rear wheel 

Information front 

wheel 
 

 

Weight / PD 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Switch on indication 

Measuring direction 

Automatic mode 

Manuel mode 

Ready indication

 

Содержание SBA 1200 GB

Страница 1: ...SBA 1200 GB SUN BRAKE ANALYSER Operating Manual HIGH TECH SECURES YOUR FUTURE ...

Страница 2: ...Operating Manual SBA 1200 GB 2 ...

Страница 3: ...Operating Manual SBA 1200 GB 3 Operating Manual SBA 1200 GB SUN BRAKE ANALYSER Copyright December 2009 Snap on Equipment GmbH All rights reserved Part number 2000618380 Rev 3 ...

Страница 4: ...Operating Manual SBA 1200 GB 4 ...

Страница 5: ...red increases in any way the liability to the customer or to third parties TO THE READER Whilst every effort has been made to ensure that the information contained in this manual is correct complete and up to date the right to change any part of this document at any time without prior notice is reserved Before installing maintaining or operating this unit please read this manual carefully paying e...

Страница 6: ...Operating Manual SBA 1200 GB 6 ...

Страница 7: ... Prevention 9 3 Display Cabinet 11 4 IR Remote Control Option 13 5 Test procedure 16 5 1 Testing the front wheel 17 5 2 Testing the rear wheel 19 5 3 Delete function 20 5 4 Enter a weight 21 5 5 Measuring ovality 21 5 6 Stopping a test 21 6 Pedal Force Transducers Optional 22 7 Printout Optional 23 8 Service Routine 24 8 1 Calibration routine 26 8 2 Clock setting 29 ...

Страница 8: ... allow easy and quick brake testing for motorcycles The test stand is particularly designed for the quick diagnosis in workshops Easy operation connected with a quick test run allows time saving and efficient brake tests one after the other after a short training period The standard version of the brake tester SUN SBA 1200 GB is equipped with the following components roller set display cabinet wit...

Страница 9: ...ch if the brake tester is not in use in order to ex clude any unallowable usage Safety regulations in operation No adjustment work with turning rollers No motor start via the test stand drive No parking on roller brake testers especially neither with the drive axle nor with engaged gear or with turned on ignition since the engine of the vehicle could start up on initiating the rollers thus risking...

Страница 10: ...ck the fastening screws of the cover plates on their tight fit in order to avoid any tyre damage when driving onto and off the test stand The access to electrical control devices such as the exchange of safety fuses not controllable from outside is only allowed to skilled workers Prior to opening the switch cabinet disconnect the system from the mains supply Keep dry all parts of the electric syst...

Страница 11: ... Manual SBA 1200 GB 11 3 Display Cabinet Actual measured brake force Information rear wheel Information front wheel Weight PD Switch on indication Measuring direction Automatic mode Manuel mode Ready indication ...

Страница 12: ...on Indicates the measuring direction Automatic Indicates that the test stand is working in automatic mode Manual Indicates that the test stand is working in manual mode Buttons Auto off Deletes automatic mode if no vehicle is in the roller set Switches off a test Auto on Activates the automatic mode Starts a test one time Cal Only required for service fault finding ...

Страница 13: ...e input by key 12 Key 2 Start the input of the total weight In case of weight input or figure input this key stands for 8 End the input by key 12 Key 3 Delete data For this purpose it is important to actuate this key twice within 5 seconds Only then all data are deleted and the automatic operation mode set on axle 1 and front axle respectively In case of weight input or figure input this key stand...

Страница 14: ... case of weight input or figure input this key stands for 1 Key 8 Switch on automatic mode start and store a measurement Test of one wheel as a service brake with automatic storing of actual axle number after ending the test Switch ON automatic operation mode if the two starting switches are in UP position In case of weight input or figure input this key stands for 2 Key 9 Stopping the roller set ...

Страница 15: ...BA 1200 GB 15 Key 11 Start ovality measurement The ovality measurement is activated by pressing this key during a running brake test Key 12 Confirm the input In case of weight input or figure input finish and store input ...

Страница 16: ...ake test as part of a MOT procedure always refer to the MOT operator manual for specific requirements a copy of the manual can be found at www motinfo gov uk When performing a brake test it is recommended that unless using the printer op tion results are manually recored after each brake is completed When testing a motorcycle with linked brakes or a sidecar with brakes the overall brake efficiency...

Страница 17: ... weight front wheel After pressing the key the rollers start up after a short waiting period Do not brake as long as the lamps are flashing at the display cabinet If the lamps have ceased flashing and no brake is applied the rolling resistance is shown on the needle Now it is possible to brake slowly and regularly up to wheel block If a pedal sensor is used the measured value is shown on the displ...

Страница 18: ...P wheel was lifted out Kind of stop front wheel 5 seconds after the roller set has stopped the efficiency of the wheel is shown on the display This efficiency is calculated after the wheel weight Efficiency front wheel Wheel weight ATTENTION If the test time is too short the display shows And the test should be repeated Now the test for the front wheel is finished and the rear wheel can be tested ...

Страница 19: ...ciency front wheel Wheel weight rear axle After pressing the key the rollers start up after a short waiting period Do not brake as long as the lamps are flashing at the display cabinet If the lamps have ceased flashing and no brake is applied the rolling resistance is shown Now it is possible to brake slowly and regularly up to wheel block If a pedal sensor is used the measured value is shown on t...

Страница 20: ...es are calculated after the total weight Efficiency rear wheel Efficiency front wheel Total weight This result is shown on the display as long as the memory is deleted 5 3 Delete function The memory should be deleted before a new test is started After the delete key is pressed the display is showing ccc and the needle for the brake force is going to half of scale Now the delete key must be pressed...

Страница 21: ...ration of the front and rear wheel is shown on the display 5 5 Measuring ovality The ovality can be tested at any time during a brake test To start the measuring hold the brake force constantly and press the button As a confirmation the both lamps for the measuring direction are flashing During this time the brake force must be constantly When the lamps are off again the brake test can be continue...

Страница 22: ...rce transducers are used Because of the different constructions of the brake handles of motorcycles there are different versions The pedal force transducers are connected to the sleeves on the left hand bottom side of the display cabinet PD 7 foot force transducer PD 8 hand force transducer PD 6 wireless force transducer for foot and hand in a set ...

Страница 23: ...Operating Manual SBA 1200 GB 23 7 Printout Optional ...

Страница 24: ...rvice routine The number of the actual test step including the respective measured value of the transducer and or sensor in mA is indicated at the display each The pointer of the indication shows always about half the value of the current The change from one test step to the next one is possible by pressing the Stop key at the display cabinet or on the remote control Sequence step meaning automati...

Страница 25: ...00 kgF 0 3000 N Active calibration check step meaning Display pointer 1 OR 1 2 3 4 5 6 7 8 Brake force 1 direction tester OR Brake force 2 direction tester Weighting unit front left Weighting unit front right Weighting unit rear Pedal force 500 N Pedal force 1000 N Slip sensor Position sensor zeropint 8 00 mA zeropint 4 00 mA zeropint 8 00 mA zeropint 8 00 mA zeropint 8 00 mA zeropint 8 00 mA zero...

Страница 26: ...in the calibration routine press the button or the AUTO ON button at step 9 in the service routine Operation Next step Last step Close the calibration routine and go back to the service routine Print the adjustments Call up the number insert Delete the last input digit ...

Страница 27: ...e pedal force rear off off 15 Inner scale 3 00 off off 16 Outer scale 3 00 off off 17 Calibration value brake force 3000 2 directions 7860 1 direction 7860 off off 18 Calibration value weighing unit 500 off off 19 Calibration value pedal force 50 off off 20 Calibration value pedal force 100 off off 21 Stepper 356 off off 22 IR code 3 off off 23 Printout kgf kgf 255 N 0 255 off off 24 No function o...

Страница 28: ...ip on display YES 255 NO 0 255 off off 37 Show last brake forces NO 255 VES 0 0 off off 38 Print automatically after test end YES 255 NO 0 0 off off 39 Time of RPM control after start in 1 10 s 15 off off 40 RPM value after switch on 240 off off 41 No function off off 42 No function off off 43 No function off off 44 No function off off 45 No function off off 46 No function off off 47 No function o...

Страница 29: ... digit In doing so it is important always to enter leading zeroes Meaning Example for the input hour ten figure 1 hour one figure 12 minute ten figure 121 minute one figure 1217 day ten figure 12171 day one figure 121710 month zero figure 1217101 month one figure 12171001 year ten figure 1217100120 year nine figure 121710012009 time date 12 17 10 01 2009 store the input and go back to the service ...

Страница 30: ...rungsvorgänge März 2009 ET Version 1 0 Anleitung erstellt 07 05 09 PL mw Version 2 0 Punkt 8 Serviceroutine ergänzt 27 11 09 IS CE Erklärung entfernt Dateiname geändert 10 12 09 Julian Woods Version 3 0 Punkt 5 Test procedure überarbeitet ...