Netra 440 Server Service Manual
• August
2004
5. Grab the metal plate at the top of fan tray 3 and pull fan tray 3 up and out of the
system (
).
FIGURE
4-18
Removing Fan Tray 3
Installing Fan Tray 3
Caution –
Do not power on the system without a functioning fan tray 3 installed.
Doing so could overheat and seriously damage the system.
Caution –
The system supplies power to fan tray 3 even when the system is
powered off. To avoid personal injury or damage to the system, you must disconnect
all AC or DC power cables before servicing the fan tray 3.
1. Align the tabs on fan tray 3 with their corresponding slots in the chassis
(
The side tab fits into a slot in the chassis side. The two bottom tabs correspond to
two slots in the bottom of the chassis.
Fan tray 3