Netra 240 Server Service Manual
• June
2004
Bezel Assembly
The bezel assembly includes the bezel, the server status indicator board, the alarm
LEDs, and the hinges (
). The assembly is replaced as a single unit.
Removing the Bezel Assembly
1. Power off the server.
See
“Powering Off the Server” on page
2. Ensure that the server is properly grounded.
See
“Avoiding Electrostatic Discharge” on page
3. Grip the bezel at the two finger holds and rotate it down to its open position
(
).
FIGURE
3-1
Finger Holds on the Bezel
4. Disconnect the bezel cables (the server status indicator cable and the alarm LED
cable) connecting the bezel assembly to the server (
CRITICAL
MAJOR
MINOR
USER
Green finger holds