Appendix B
System Specifications
197
Reference for Environmental
Requirements
The operating and non-operating environmental requirements for the system are
as follows.
Parameter
Value
Operating
Temperature
5˚C to 35˚C (41˚F to 95˚F)—IEC 68-2-1, 68-2-2
Humidity
20% to 80% RH, noncondensing; 27 ˚C max wet bulb—IEC 68-2-2,
68-2-3
Altitude
0 to 3000 meters (0 to 10,000 feet)—IEC 68-2-40, 68-2-41
Vibration:
Deskside
Rackmounted
0.0002 g
2
/Hz, 5–500 Hz (random)—IEC 68-2-6
0.00015 g
2
/Hz, 5–500 Hz (random)—IEC 68-2-6
Shock:
Deskside
Rackmounted
4 g peak, 11 milliseconds half-sine pulse—IEC 68-2-27
3 g peak, 11 milliseconds half-sine pulse—IEC 68-2-27
Declared Acoustics
6.7 bels dB(A) operating, 7.6 bels dB(A) at
ok
prompt
Non-Operating
Temperature
-20˚C to 60˚C (-4˚F to 140˚F)—IEC 68-2-1, 68-2-2
Humidity
95% RH, noncondensing at 40˚C—IEC 68-2-2, 68-2-3
Altitude
0 to 12,000 meters (0 to 40,000 feet)—IEC 68-2-40, 68-2-41
Vibration:
Deskside
Rackmounted
0.002 g
2
/Hz, 5–500 Hz (random)—IEC 68-2-6
0.0015 g
2
/Hz, 5–500 Hz (random)—IEC 68-2-6
Shock:
Deskside
Rackmounted
15 g peak, 11 milliseconds half-sine pulse—IEC 68-2-27e
10 g peak, 11 milliseconds half-sine pulse—IEC 68-2-27e
Handling Drops
50 mm—IEC 68-2-31
Threshold Impact
1 m/s—SUN 900-1813
Содержание Fire 880
Страница 6: ...vi Sun Fire 880 Server Owner s Guide August 2001...
Страница 8: ...viii Sun Fire 880 Server Owner s Guide August 2001...
Страница 14: ...xiv Sun Fire 880 Server Owner s Guide August 2001...
Страница 40: ...22 Sun Fire 880 Server Owner s Guide August 2001...
Страница 106: ...88 Sun Fire 880 Server Owner s Guide August 2001...
Страница 120: ...102 Sun Fire 880 Server Owner s Guide August 2001...
Страница 176: ...158 Sun Fire 880 Server Owner s Guide August 2001...
Страница 204: ...186 Sun Fire 880 Server Owner s Guide August 2001...
Страница 212: ...194 Sun Fire 880 Server Owner s Guide August 2001...
Страница 218: ...200 Sun Fire 880 Server Owner s Guide August 2001...