Sun Quad FastEthernet 6U CompactPCI Adapter Installation and User’s Guide • June 2000
The hot-swap LED shows whether the adapter has been activated.
■
If the hot-swap LED is OFF (unlit), the I/O slots in the server have been set to full
hot swap and the adapter has been activated. Go to Step 15.
■
If the hot-swap LED is ON, then the I/O slots in the server have been set to basic
hot swap. You must use software commands to activate the I/O card. Go to
Step 11.
Note –
You should also use the hot-swap LEDs on the server when installing the
adapter. For example, Netra ct servers contain an OK to Remove LED (
) on the
system status panel that is used like the hot-swap LED on this adapter. Refer to your
system’s service manual for a description on how the hot-swap LEDs are used
during a hot-swap installation.
11. Remove the wrist strap from the chassis and from your wrist.
12. Log in to the server.
Refer to the server’s documentation for the procedure.
13. At the terminal prompt, type the hot-swap software commands to identify and
attach the adapter to the server.
These commands may be specific to the server’s hot-swap software. Refer to the
server’s documentation for the correct commands and procedures.
For example, if you are installing the adapter into a Netra ct server, you would use
the
cfgadm pci
command to list the attachment point IDs in the server. On a
Netra ct 800 server, you should see feedback similar to the following:
Once you have identified the attachment point ID on the Netra ct server, you can use
the following commands to attach the adapter to the server:
# cfgadm pci
Ap_Id
Type
Receptacle
Occupant
Condition
pci_pci0:cpci_slot2
unknown
empty
unconfigured
unknown
pci_pci0:cpci_slot3
stpcipci/fhs
connected
configured
ok
pci_pci0:cpci_slot4
stpcipci/fhs
connected
configured
ok
pci_pci0:cpci_slot5
unknown
empty
unconfigured
unknown
pci_pci0:cpci_slot6
unknown
empty
unconfigured
unknown
pci_pci0:cpci_slot7
unknown
empty
unconfigured
unknown
pci_pci0:cpci_slot8
stpcipci/fhs
connected
configured
ok
# cfgadm -c connect
attachment-point-id
# cfgadm -c configure
attachment-point-id