Sun Datacenter Switch 3456 Installation Guide • December 2008
6. Verify that the green Connected LED is lit for each power supply.
If one or more LEDs are not lit, for the respective power supply, determine
whether the power supply or the power cable is faulty. For each power supply
with an unlit LED, use a different power cable.
■
If that same LED is still not lit, replace the power supply.
■
If that same LED is now lit, replace the power cable.
Note –
At this time, power is being supplied to the CMCs. The CMCs are effectively
on.
Power Supply Administrative
Commands
This section provides basic commands to administrate power supplies when they are
first installed. Some commands require you to reference
.
▼
To Power On Power Supplies
When the power is applied to the power supplies, a standby voltage is present. The
CMC can instruct the power supply to turn on to full power.
TABLE 10-1
Power Supply Slot Mapping
Power
supply
PS8
PS9
PS10
PS11
PS12
PS13
PS14
PS15
Slot
8
9
10
11
12
13
14
15
Power
supply
PS0
PS1
PS2
PS3
PS4
PS5
PS6
PS7
Slot
0
1
2
3
4
5
6
7
Содержание Datacenter Switch 3456
Страница 10: ...x Sun Datacenter Switch 3456 Installation Guide December 2008 ...
Страница 14: ...xiv Sun Datacenter Switch 3456 Installation Guide December 2008 ...
Страница 20: ...6 Sun Datacenter Switch 3456 Installation Guide December 2008 ...
Страница 48: ...34 Sun Datacenter Switch 3456 Installation Guide December 2008 ...
Страница 49: ...Chapter 5 Unpacking the Chassis 35 ...
Страница 73: ...58 Sun Datacenter Switch 3456 Installation Guide December 2008 ...
Страница 87: ...72 Sun Datacenter Switch 3456 Installation Guide December 2008 ...
Страница 97: ...82 Sun Datacenter Switch 3456 Installation Guide December 2008 ...
Страница 125: ...110 Sun Datacenter Switch 3456 Installation Guide December 2008 ...