background image

ADDITIONAL SAFETY INSTRUCTIONS FOR YOUR GENERATOR

Electrical generators must always be grounded, (connected to earth).
Petrol or diesel powered generators must never be used in an unventilated closed spaces.The
exhaust fumes are highly dangerous and can cause “Carbon Monoxide Poisoning” which will
cause drowsiness and death.
The generator must be mounted on a firm level surface.
The electrical output load must not exceed the maximum load stated on the rating plate.
Exceeding the rated load will damage the unit or shorten its life and will invalidate the
guarantee.
The engine must not be run at speeds that exceed the maximum stated on the rating plate.
Operating an engine at excessive speeds increases the hazard of personal injury.
Do not tamper with components, which may increase or decrease the governed speed.
Mains extension leads, mains supply leads, and all electrical equipment must be in good working
condition.
Never operate electrical equipment with damaged or defective mains supply leads.
Keep the area around the generator clear of obstructions at all times. Never locate the
generator against a building or near a canvas or plastic structure i.e.Tents etc.
Always use the correct fuel mix as stated in the user manual and on the rating plate.
To prevent fire, always stop the engine when refueling and never over fill the fuel tank.
Always clean up spilt fuel immediately using sand.
Do not use the generator in or near an explosive atmosphere.
To prevent an electric shock, never operate the machine in rain, snow or touch with wet
hands.
Check the fuel system periodically for leaks. Seals and hoses should be checked for signs of
deterioration or chafing. Check for loose or missing clamps damaged fuel tank or filler cap. All
defects should be corrected before further use.
Always allow the generator to reach full operating speed before connecting any electrical load.
Always disconnect the electrical load before switching the generator off.
To prevent surging that may possibly damage electrical equipment, do not allow engine to run
out of fuel while electrical loads are connected.
Before transporting the generator in a vehicle, drain all fuel to prevent spillage.
To prevent an electric shock and fire, never connect an electrical load with the electrical
output switched on.
Do not connect the generator to any other electrical source.
Store the generator in a well-ventilated area with the fuel tank empty.

FUEL FILLING SAFETY INSTRUCTIONS

Warning!

Select bare ground for fuelling and move at least 10 feet (3m) from fuelling spot before starting the
engine.After refuelling, properly tighten fuel cap; wipe off any spilled fuel and check for leakage.

Warning!

If fuel gets spilled on clothes, especially trousers, it is very important to change clothes immediately. Do
not rely on evaporation.

Содержание SMK37GEN

Страница 1: ......

Страница 2: ...2400w PORTABLE GENERATOR SMK37GEN SAFETY AND OPERATING MANUAL Full Manufacturer s Warranty...

Страница 3: ...n this period contact your retailer GUARANTEE This Sumo product carries a guarantee of 12 months If your product develops a fault within this period you should in the first instance contact the retail...

Страница 4: ...expose power tools to rain or wet conditions Water entering a power tool will increase the risk of electric shock d Do not abuse the cord Never use the cord for carrying pulling or unplugging the pow...

Страница 5: ...ool if the switch does not turn it on and off Any power tool that cannot be controlled with the switch is dangerous and must be repaired c Disconnect the plug from the power source before making any a...

Страница 6: ...refueling and never over fill the fuel tank Always clean up spilt fuel immediately using sand Do not use the generator in or near an explosive atmosphere To prevent an electric shock never operate th...

Страница 7: ...stated on the rating plate Operating an engine at excessive speeds increases the hazard of personal injury Do not tamper with components which may increase or decrease the governed speed Mains extens...

Страница 8: ...s practice endangering attachments and the user Store the generator in a well ventilated area with the fuel tank empty SYMBOLS Read the manual Wear ear protection Warning Wear eye and dust protection...

Страница 9: ...AC socket 240v 6 AC socket 110v 7 Engine switch 8 Ground earth terminal 9 Oil drain plug 10 Recoil starter 11 AC circuit breaker 12 DC Socket 13 DC circuit breaker 14 Pilot light 15 Voltmeter 16 AC sw...

Страница 10: ...fe working levels Whilst there is a correlation between the emission and exposure levels this cannot be used reliably to determine whether or not the actual level of exposure of the workroom the other...

Страница 11: ...n Earth spike can be made and it is suggested you get advice from a registered electrical trades person To make a Spike use a Copper tube or Copper Rod 12mm diameter a minimum length of 200mm and with...

Страница 12: ...ge the oil according to the maintenance schedule on page 17 or if contaminated 3 FUELING Check fuel level If fuel level is low refill with unleaded petrol Be sure to use the fuel filter screen on the...

Страница 13: ...been successfully started and is running smoothly return the choke lever to the OFF position See Fig 9 Warning Before connecting any electrical load to the generator ensure that the load does not exce...

Страница 14: ...TION The generator is fitted with 2 overload protection devices located on the control panel In the event that the load exceeds that stated on the rating plate the overload protection will operate and...

Страница 15: ...meter measure the specific gravity of the battery fluid and calculate the charging time in accordance with the table shown in Fig 14 Attach the 12v charging leads to the battery observing correct pola...

Страница 16: ...f the deposits on the end of the spark plug it should be a Tan colour Remove all deposits using a stiff brush a brass wire brush is ideal See Fig 17 Check the spark plug gap and adjust if required The...

Страница 17: ...emove the spark plug and pour approximately one tablespoon full of clean engine oil into the spark plug hole With the ignition turned OFF gently pull on the recoil starter cord several times Re fit th...

Страница 18: ...Clean fuel cock filter Replace if required Valve Check and adjust when Clearance engine is cold Fuel line Check fuel hose for cracks or damage Replace if required Exhaust Check for leakage Tighten or...

Страница 19: ...ged fuel line No fuel in tank Fuel tap not open ELECTRIC SYSTEM PROBLEMS Combustion chamber supplied with fuel Poor spark Pull rope sharply Clean tank Clean fuel line with dealers advice Supply fuel O...

Страница 20: ...No AC output Tripped circuit breaker Reset CONDITION PROBABLE CAUSE CORRECTIVE ACTION Poor connection or faulty lead Broken recepticle Faulty circuit breaker Check and repair Check and repair Generat...

Страница 21: ...2400w PORTABLE GENERATOR SMK37GEN...

Страница 22: ......

Страница 23: ...2400w PORTABLE GENERATOR SMK37GEN...

Страница 24: ...rective 2006 95 EC Low Voltage Directive 98 37 EEC Machinery Directive 2000 14 EC Noise Directive Standards and technical specifications referred to EN 55014 1 2000 A1 2001 A2 2002 EN 55014 2 1997 A1...

Отзывы: