f) Connect range to gas supply at appliance pressure regulator using adapters supplied
with flexible connector. Rigid pipe may also be used. See rating plate for type of gas
range has been manufactured for.
g) Turn on main gas valve at meter, and relight pilots at other gas appliances.
h) Apply a non-corrosive leak detection fluid to all joints and fittings in the gas connection
between the supply line shut-off valve and the range. Include gas fittings and joints in
the range if connections were disturbed during installation. Check for leaks! Bubbles
appearing around fittings and connections will indicate a leak. If a leak appears, turn off
gas supply line shut-off valve, tighten connections, turn on the gas supply line shut off
valve, and retest for leaks.
CAUTION: NEVER CHECK FOR LEAKS WITH A FLAME.
WHEN LEAK CHECK IS COMPLETE, WIPE OFF ALL RESIDUE.
i) Remove shipping polystyrene from oven cooking cavity. This is to hold the burners in
place on the burner base for shipping purposes only.
Checking Pressure of House Piping System
1) The appliance and its individual shut-off valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test pressure in
excess of ½ lbs./sq. in. (3.5 kPa or 13.8 in. water column).
2) The appliance must be isolated from the gas supply piping system by closing its
individual manual shut-off valve during any pressure testing of the gas supply piping
system at test pressure equal to or less than ½ lbs./sq. in. (3.5 kPa or 13.8 in. water
column).
GAS CONVERSION
All ranges are equipped with both Natural Gas and LP Gas injectors as well as a
convertible appliance pressure regulator. The unit model number plate states which gas it
was adjusted for at the factory. To convert the unit to either Natural gas or LP gas will
require switching burner injectors, burner adjustment for low flame and adjustment of the
appliance pressure regulator converter cap.
Inlet pressure to the appliance pressure regulator should be as stated in the chart on page
14 for both operation and checking of appliance pressure regulator setting.
To Convert the Gas Oven
1) Replacement of the injectors
First, electrically disconnect the oven and close the ball valve supplying the gas with
thermostat knob.
To replace the injectors, remove the screw fixing the burner to the front part (for the
oven burner it is first necessary to extract the removable top
“
P
”
fig. n°13). Cautiously
extract the burner
“
B
”
from the rear seat, being careful not to shake the thermocouple
and the ignition spark plug cable.
Содержание SGWO30SS
Страница 16: ...16 SUMMIT 201805 GAS OVEN SGWO30SS MANUAL FIGURES Fig n 01 Fig n 02 Fig n 03 Fig n 05 Fig n 06 Fig n 07...
Страница 17: ...17 SUMMIT 201805 GAS OVEN SGWO30SS MANUAL Fig n 09 Fig n 10 Fig n 11 Fig n 11A...
Страница 18: ...18 SUMMIT 201805 GAS OVEN SGWO30SS MANUAL Fig n 12 Fig n 13 Fig n 13A Fig n 14...
Страница 19: ...19 SUMMIT 201805 GAS OVEN SGWO30SS MANUAL WIRING DIAGRAM...