background image

INSTALLATION INSTRUCTIONS 

 

This appliance is meant for free-standing installation; it should not be built-in.

 

 

Do not put heavy items on top of the unit.

 

 

Do not store or install the appliance outdoors. 

 

This appliance is designed for the storage and display of frozen items 
Do not use it to store medicine or other medical products. 

Moving and Installing Your Appliance 

  When transporting, keep the unit vertical as much as possible.  The angle between the vertical and the 

side of the unit should never exceed 40° since this could affect the compressor and result in abnormal 
operation. 

  After unpacking the unit, remove the packing materials and place the unit on a level and sturdy floor 

near a power socket. 

  Leave at least 4" of space between the back of the unit and the wall for ventilation.  Leave space 

enough  to allow the door to swing open 160°. 

  Keep the unit away from heat sources and avoid direct sunlight. 

  Never place the unit in a location with high humidity or where water can reach it. 

  It is recommended that you install the appliance in a place where the ambient temperature is between 

72º and 78ºF (23º-26ºC).  If the ambient temperature is above or below the recommended 
temperatures, the performance of the unit may be affected.  For example, placing your unit in extreme 
cold or hot conditions may cause interior temperatures to fluctuate.  

 

 

Electrical Connection 

 

 

 
 
Improper use of the grounded plug can result in the risk of electrical shock. If the power cord is 
damaged, have it replaced by a qualified electrician or an authorized service center. 

Never ground the unit through a gas pipe, tap water pipe or the grounded wire of a single-phase 
power supply. 

 
 
 
 

 
 
 
 
This appliance should be properly grounded for your safety.  The power cord of this appliance is equipped 
with a three-prong plug which mates with standard three-prong wall outlets to minimize the possibility of 
electrical shock. 

Do not under any circumstances cut or remove the third (ground) prong from the power cord supplied. For 
personal safety, this appliance must be properly grounded. 

This appliance requires a standard 115/120 Volt AC ~ 60Hz three-prong grounded electrical outlet. Have 
the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded. 
When a standard 2-prong wall outlet is encountered, it is your responsibility and obligation to have it 
replaced with a properly grounded 3-prong wall outlet.  

To prevent accidental injury, the cord should be secured behind the appliance and not left exposed or 
dangling. 

The appliance should always be plugged into an exclusive, properly grounded wall outlet which has a 
voltage rating that matches the rating label on the appliance. This provides the best performance and also 
prevents overloading house wiring circuits that could cause a fire hazard from overheating. Never unplug 

 

6

Содержание SCFU1375

Страница 1: ...Instruction Manual BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS Write Serial No on back of unit here ________________________________ Felix Storch Inc 770 Garrison Ave...

Страница 2: ...ord 7 Operating Your Appliance 7 8 Turning On the Unit 7 Storing Items in the Unit 7 Setting and Adjusting the Temperature 7 8 Defrosting the Unit 8 Interior Lights 8 Door Lock 8 Shelves 8 Normal Phen...

Страница 3: ...ctions are not followed IMPORTANT SAFEGUARDS Before the appliance is used it must be properly positioned and installed as described in this manual so read the manual carefully To reduce the risk of fi...

Страница 4: ...nce with the National Electrical Code and local codes and ordinances is required Do not kink or pinch the power supply cord of the appliance The size of the fuse or circuit breaker should be 15 ampere...

Страница 5: ...on grid Cabinet Digital temperature control and display Caster TECHNICAL INFORMATION Model SCFU1375 Installation Free standing Capacity 11 2 cubic feet Electrical Input 115V AC 60Hz Rated Current 1 4A...

Страница 6: ...eratures to fluctuate Electrical Connection Improper use of the grounded plug can result in the risk of electrical shock If the power cord is damaged have it replaced by a qualified electrician or an...

Страница 7: ...rn it on Be sure the door is closed After half an hour the temperature inside the cabinet should have cooled down if so the unit is operating normally CAUTION If power is disconnected do not try to re...

Страница 8: ...s both lights on and off Door Lock Your unit is provided with a lock and set of keys The keys are located inside the plastic bag that contains the Instruction Manual Insert the key into the lock and t...

Страница 9: ...g cleaning could result in electrical shock or other personal injury Bulb Replacement When the bulbs behind the lighted logo panel must be replaced 1 Remove the left side cover of the light box You ll...

Страница 10: ...ith a blanket or similar covering Power Cord If the power cord is damaged it must be replaced by the manufacturer its service agent or a similarly qualified person in order to avoid an electrical haza...

Страница 11: ...tment for repair suggestions There is frost or ice on the walls of the inner cabinet and the internal temperature is too low The compressor operates continuously The thermostat sensor has separated fr...

Страница 12: ...nited States 5 Repairs to parts or systems resulting from unauthorized modifications made to the appliance 6 Expenses for travel and transportation for product service in remote locations 7 The remova...

Отзывы: